23
MOBILE HOME INSTALLATION
Mobile home installation should be done in accordance with the Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
In order for this unit to be installed in a mobile home the following criteria must be met:
•
The unit must be secured to the floor using lag bolts in the holes provided in the
pedestal base.
•
Ensure that the unit is permanently electrically grounded to the chassis of your
home.
IT IS MANDATORY TO TAKE THE COMBUSTION AIR FROM THE OUTSIDE
WHEN INSTALLING THIS UNIT IN AIR TIGHT OR MANUFACTURED/MOBILE
HOMES.
CAUTION:
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR,
WALL, AND CEILING/ROOF MUST BE MAINTIANED.
WARNING:
DO NOT INSTALL IN SLEEPING ROOM.
STEEL FRAME
1/4" LAG BOLTS,
SECURELY FASTENED
GROUND WIRE, DIRECTLY
TO METAL CHASSIS
FLOORING
Figure 13