Operating the Tandem Center 4-Way Control Valve with Huck Tooling
1. Turn the valve control lever to the NEUTRAL position.
2. Start the pump by pressing and holding the tool trigger switch.
3. Turn lever to Pull Side, Huck tool will pull back installing the fastener. (Cutting the collar if cutter nose is
used)
4. Turn lever to Return Side, Huck tool will return to full forward position pushing off collar (releasing
cutter if used).
NOTE: The cylinder momentarily loses pressure during the transition between valve positions.
5. Turn the valve control lever to the NEUTRAL position. Shut the pump off by releasing the tool trigger
switch.
Model 964B Powerig®