background image

PROBLEM

CAUSE

SOLUTION

Pump will not build

full pressure.

1. Check for external leakage.

2. Improperly adjusted external

pressure regulator setting.

3. Internal or external leakage on

hydraulic tool.

4. Inadequate power supply.
5. Leaking control valve or defective 

pump.

1.

pipes or hoses.

2.

Center 4-Way Control Valve with Huck Tooling”

on page 11.

3. Remove the tool from the pump. If the pump 

builds full pressure, the tool is defective. Contact 

your Huck distributor.

4. Refer to “Pump Operation” section on page 10.
5. Contact your Huck distributor.

Tool(s) will not pull or 

return.

1. Quick disconnect couplings are not 

completely coupled.

2. Broken return spring in spring-re-

turn tool or seal blown in double-act-

ing tool.

1. Check quick disconnect coupling to tools to 

ensure that they are completely coupled.

Occasionally couplers have to be replaced 

because the ball check does not stay open due to 

wear.

2. Contact your Huck distributor.

Troubleshooting

WARNINGS: 

A double acting tool must 

have both hoses and all 

couplers securely connect-

ed to both ports. If one of 

the two ports is restricted 

or becomes disconnected, 

pressure will build and the 

tool, hose or coupler can 

burst, possibly causing seri-

ous injury or death.

15

Содержание HOWMET AEROSPACE Powerig 964B

Страница 1: ...ulic Diagram 7 Set up Instructions 8 Hydraulic Fluid Filling the Bladder 8 Charge Battery Battery Set up 9 Attach Operate the Control Cable 9 Bleeding the System 10 Pump Operation 10 Setting the Press...

Страница 2: ...urbance Characteristics Limits and Methods of Measurement ISO 12100 2011 Safety of machinery basic concepts general principles for design risk assessment and risk reduction ISO 4413 2010 Hydraulic Flu...

Страница 3: ...radius see chart below Do not use in temperatures less than 40 C 40 F or greater than 100 C 212 F 70 C 158 F Do not use if hose is kinked abraded cut bulged or leaking Do not attempt to repair hose Do...

Страница 4: ...18 Tools with ejector rods should never be cycled with out nose assembly installed 19 When two piece lock bolts are being used always make sure the collar orientation is correct See fastener data shee...

Страница 5: ...o prevent work piece from ringing 3 Use hearing protection in accordance with employer s instructions and as required by occupational health and safety regulations 4 Operate and maintain tool as recom...

Страница 6: ...er is released the motor turns off The motor may also be started by pressing the start button on the handle of the unit behind the valve but this button is overridden when the supplied control cable i...

Страница 7: ...when the Control Cable is connected to the pump unit the tool the Control Cable is connected to the pump unit the tool trigger overrides the on off switch The 3 position 4 way manual valve controls th...

Страница 8: ...normal pressures will cause premature wear of equipment If the maximum pressure is exceeded violent failure of fastening system may occur This may cause severe personal injury Electric Motor WARNING T...

Страница 9: ...ge the Battery New batteries must be charged Approx 60 minutes of charging 100 battery fuel A Ensure battery charger is plugged in B Slide battery pack into charger as shown and allow battery to charg...

Страница 10: ...s Connect hydraulic hoses from a HUCK hydraulic tool to the Powerig CHECKING PRESSURES WARNINGS above must be understood Check PULL and RETURN pressures before use before troubleshooting tool instruct...

Страница 11: ...ck installing the fastener Cutting the collar if cutter nose is used 4 Turn lever to Return Side Huck tool will return to full forward position pushing off collar releasing cutter if used NOTE The cyl...

Страница 12: ...s Accessories These components are available independently DESCRIPTION PART 220 240 VAC Battery charger MWCH 18 240 Gauge Pressure Setting CE T 124833CE Spare Parts for Maintenance These components ar...

Страница 13: ...ved high grade hydraulic oil 215 SSU 100 F 4 Replace filler cap Important Tighten filler cap 1 2 1 turn after o ring contacts sealing surface Overtightening can cause pump damage Note For more complet...

Страница 14: ...g to directions Filling The Pump Bladder under Set up In structions section 2 Check quick disconnect couplings to tools to ensure that they are completely coupled Occa sionally couplers have to be rep...

Страница 15: ...Contact your Huck distributor Tool s will not pull or return 1 Quick disconnect couplings are not completely coupled 2 Broken return spring in spring re turn tool or seal blown in double act ing tool...

Страница 16: ...d information regarding each application and or use of such products 2022 Howmet Aerospace Inc Howmet Fastening Systems Kingston Operations 3 s s e 1 5 3 m e 6 4 5 m s 7 e 7 5 5 m 7 n 4 5 s d 8 3 0 m...

Отзывы: