8.5
Electrical connections
8.5.1. Identification of the winch’s electrical cables
8.5.2. Mains supply
Check that the network voltage corresponds to the one required for the machine.
Measure the real value of this voltage. There should be no more than a 5% difference between it and the
nominal value.
The machine should be connected to an electrical line with the correct protection devices: fuse/protective
circuit breaker, main circuit breaker.
Very important:
the winch will only provide full power if the motor is supplied via a cable section which is suited to
this use.
Recommended power cable section:
VOLTAGE
TYPE
Section of power cable
Power
Length 10 m
Length 30 m
220 V mono.
2 + T
2,5 mm²
4,0 mm²
0,75/1,1 kW
230 V tri.
3 + T
1,5 mm²
2,5 mm²
0,75/1,1 kW
3 + T
2,5 mm²
4,0 mm²
2,2/3 kW
3 + T
2,5 mm²
6,0 mm²
5,5 kW
400 V tri.
3 + T
1,5 mm²
1,5 mm²
0,75/1,1 kW
3 + T
1,5 mm²
2,5 mm²
2,2/3 kW
3 + T
2,5 mm²
4,0 mm²
5,5 kW
Power supply via a generator is possible: minimum power in kVA equal to or greater than five times the motor
power in kW.
Power supply
Remote control
Speed variation version (optional)
Power supply
Socket
(remote
control)
Low Voltage version