U-ONE
®
-SAFETY Compact
Configuration manual SCU C / SRC C / SGS C
12
USC42_SCU-KonfigManual-en_R5
Level 1:
Tester (password level 1)
On this level the following functions are available in
addition to those on level 0:
- Perform test of switch
- Generate test logs
Level 2:
Admin (password level 2)
On this level the following functions are available in
addition to those on level 1:
- Change parameters
- Save parameter sets
Default passwords on delivery are 'huebner1' for
password level 1 and 'huebner2' for password level 2.
A padlock with an open shackle symbolizes that the
password “huebner2”
has not yet been changed;
consequently, the configuration is not secured against unauthorized changes.
A closed padlock shackle indicates the configuration is securely protected against
unauthorized changes. How to save the configuration is described in chapter 5.4.
The authorization level is displayed in plain text to the left of the padlock symbol
(here the level is: Admin), with which the user is logged into the USC 42.
PLEASE NOTE!
The login password is set ex-works to 'huebner1' or 'huebner2'.
ATTENTION!
Change the Admin password as soon as possible to protect the configuration from
unauthorized access! (See chapter 4.1.8).
4.1.9 Pulldown menu: Options
firmware update
The USC 42 is prepared for a firmware update by electrically connecting terminal 1 (+ U)
and terminal 2 (Error1) during power up. After switching on, this connection must be
removed again.
The button.………..selects the update file.
„Transfer“ starts the update process.
After the update process, the device must be restarted.
NOTE!
Before the restard, the connection
must be removed.
Fig. 4-5: Partial view header
Fig. 4-6: firmware update