Operating manual HBG 800-DP
Rev. 05 - 08/18
Hubitron Steuerungstechnik
Hubitron Steuerungstechnik, Hauptstr. 4/1, D-89611 Obermarchtal, Germany, Tel. +49(0)7375/922066, FAX +49(0)7375/922077
12 of 16
16. LED's in the access point
In the access point are 10 LED's. They show the
status and function of the unit:
LED1:
ready status / operation
LED2:
transmitting
LED3:
hand terminal in charging station
blinking: fast charge
LED4:
hand terminal in charging station
blinking: error in supply voltage
or defekt in the unit
In addition each relay has a LED which displays the
status of the output relay.
The jumper must be set to 1 + 2!
16.1
LED's in the connecting adaptor
LED1
LED2 description
on
on
ready for use, Profibus active
blinking
on
error in the connetion to the
access point or access point
defect
blinking
off
Profibus connection inactive
off
off
no power supply