Operating manual HBG 800-DP
Rev. 05 - 08/18
Hubitron Steuerungstechnik
Hubitron Steuerungstechnik, Hauptstr. 4/1, D-89611 Obermarchtal, Germany, Tel. +49(0)7375/922066, FAX +49(0)7375/922077
10 of 16
13. Maintenance and care
For a continuous and safe operation the following
points need to be attended regularly:
-
Clean the hand terminal monthly from any dirt,
wipe off coolant residues and other fluids
immediately.
-
Clean the charging contacts on the charging
station and the hand terminal monthly, i.e. with
spirit (Danger: be careful – with flammable
fluids).
-
Always clean the magnet on the hand terminal
from swarf or splinters before returning it to the
charging station!
-
Once a month run the batteries from the hand
terminal down without charging to LOW-BATT -
this increases the strength of the battery
charge.
-
Change rechargeable batteries every 2 years.
-
Check the emergency stop monthly!
13.1
Change of rechargeable batteries
The batteries should be preventatively changed
every 2 years. Only use NiMh-rechargeable
batteries (Size AA) with a capacity of min.
2100mAh.
Suggested types:
manufacturer
capacity
GP
2100 mAh
Panasonic
2100 mAh
Sanyo
2100 mAh
13.1.1 Exchange of rechargeable batteries
-
push the emergency stop on the hand terminal
-
take out the 6 screws S from the housing
S
S
S
S
S
S
-
Carefully lift the housing lid and pull off
connection X
-
Put housing cover aside
X
-
pull off plug A, B, C + D
-
remove the 4 screws E
-
take out and turn conductor board P
A
B
C
D
E
E
E
E
P