10. Error solutions
Error
possible cause
solution
display:"no wire!"
- wire outside measuring range
- incidence of extraneous light
- wire too thin
- wire slag too big
check and correct wire position
use black light protector cap
use wire with 0.2 – 0.3 mm Ø
adjust wire tension
blinking
accu nearly empty
charge accu
no radio connection to
the ACS-1000 RC
ID is not matching with the ACS-1000
check and change ID
no display of length
position
- out of range
- reflection area too dark
- too much foreign light on the reflection area
- sight glas dirty
divide measurements in sections
use brighter reflector (white)
install light protectors (i.e. window blinds)
clean sight glass
measured values not
plausible
- incidence of extraneous light
- system not compensated
- too much dirt on sensor head
- system focus out of alignment
- accu is loading
use provided black light protector cap
run compensation
send unit for service
check position of machine slide
(see chapter 8.5)
during the loading process there are
larger voltage fluctuations, which can
distort the measurements
display remains dark
- accu empty or defect
- fuse defect
- unit defect
charge accu resp. have accu changed
change fuse (chapter 12.1)
send unit for service
display non-readable
altered contrast
Readjust contrast
11. Activity to avoid interruptions
1. If the unit is not in use cover the sensor head
with the red protector cap to minimize pollution
2. During operation cover the sensor head with
the black protector cap to avoid strong
exposure to light and pollution
3. During measurements protect the ACS-1000
from exposure to direct solar radiation and high
temperature fluctuations
4. For safekeeping store the ACS-1000 in the
provided transport case when not used
11.1 Service address
Hubitron Steuerungstechnik
Hauptstr. 4/1
89611 Obermarchtal / Germany
Tel: 07375/92 20 66
Fax: 07375/92 20 77
Email: [email protected]
Internet: www.Hubitron.de
12. Maintenance and care
For a continuous and safe operation of the ACS-
1000 comply with the following steps:
•
After use clean the unit with a clean and damp
cloth.
Do not use compressed air!
•
Before each new measuring operation clean
sight glas with a clean and damp cloth.
•
Charge the accu every 6 months, even if not in
use at the time.
•
Protect sensor head with the provided red
protector cap from pollution when not in use.
•
Store the ACS-1000 always in the provided
transport case.
12.1 Change fuse
Should the ACS-1000 not function anymore, the
fuse might be defect. Installed is a microfuse 5x20
with 2AT.
•
shut off unit
•
take off the aluminum blinds of the housing
•
loosen the 4 outer screws
•
flip cover to the side
•
check and possibly change the fuse on the
board