Seite 6 von 14

  position machine slide on the left outer stop

  adjust  wire  sideways  until  the  deviation  is

< 1mm

8.3 Height compensation

In  order  to  avoid  a  measurement  mistake  through

the  wire  slag,  a  compensation  of  the  height  is

absolutely required.

  start height compensation:

main menu - 

 - 

follow the instructions on the display

  arrange  machine  slide  that  the  wire  is  in  the

center and 

 is displayed

  confirm with 

ATTENTION:

Now do not move the Z axis anymore!

  move 

machine 

slide 

up 

until

H = +4.5 mm and 

 

is displayed

  confirm with 

NOTE:

Is  the  deviation  larger  0.1  mm,  the  incline  of  the

sensor  head  must  be  corrected  with  the  knurled

screw  (see  8.3.1).  The  compensation  starts

automatically again at the beginning.

  move 

machine 

slide 

down 

until

H = -4.5 mm and 

 is displayed

  confirm with 

NOTE:

Is  the  deviation  larger  0.1  mm,  the  incline  of  the

sensor  head  must  be  corrected  with  the  knurled

screw  (see  8.3.1).  The  compensation  starts

automatically again at the beginning.

8.3.1 Adjustment of incline

When  doing  the  height  compensation  it  is  possibly

necessary  to  adjust  the  incline  of  the  sensor  head.

To adjust use the knurled screw.
One turn of the knurled screw changes the incline by

appr. 0.025 mm at a height of 4.5 mm.

Содержание ACS-1000

Страница 1: ...ation and arrangement 4 8 1 1 Installation 4 8 1 2 Arrangement 5 8 2 Wire spanning and arranging 5 8 3 Height compensation 6 8 3 1 Adjustment of incline 6 8 4 Length compensation 7 8 4 1 Delete compen...

Страница 2: ...t case ACS 1000 1 Protector cap for sensor red 1 Light protector cap black 1 Inbus key SW4 4 Optional equipment 4 1 Remote control ACS 1000 RC With the remote control ACS 1000 RC all relevant function...

Страница 3: ...play This display appears for appr 2 seconds when the unit is switched on The SW version and the ID for the remote control is displayed 7 2 2 Main menu On the bottom the assignment of the function key...

Страница 4: ...rmation the next instruction will follow back to the compensation menu 7 2 5 Starting menu Graphic display set display data to 0 set display data to absolut switch to text display back to the compensa...

Страница 5: ...heet of paper DIN A4 position machine at the right outer stop arrange ACS 1000 that the laser beam remains within the reflection area A sideways deviation can be corrected by turning the ACS 1000 on t...

Страница 6: ...ION Now do not move the Z axis anymore move machine slide up until H 4 5 mm and is displayed confirm with NOTE Is the deviation larger 0 1 mm the incline of the sensor head must be corrected with the...

Страница 7: ...Is the length compensation not needed the last compensation data must be deleted start length compensation main menu delete data with 8 5 Start measurements Is the ACS 1000 arranged and compensated th...

Страница 8: ...esp have accu changed change fuse chapter 12 1 send unit for service display non readable altered contrast Readjust contrast 11 Activity to avoid interruptions 1 If the unit is not in use cover the se...

Страница 9: ...Charge goes off the charging process is finished 12 3 Change accu Is the accu running time considerably declining the accu might be defect and must be changed For an accu change the unit must be sent...

Страница 10: ...3 5 Charge accu connect the provided charging unit type ACS 110 with the connector of the ACS 1000 RC connect charging unit with the electrical network The red LED Charge indicates the charging proces...

Страница 11: ...tall the Software net Framework from Microsoft is required Is it not yet installed it will be automatically downloaded and installed during the installation Internet connection is required On the CD a...

Страница 12: ...disrupted 2 Transmit data record to table On the chosen measuring points each data record must be transmitted to the table 3 Print chart A window appears for customer and machine data Enter the custom...

Страница 13: ...ner Huber eMail Info Hubitron de www Hubitron de 02 08 2012 Manufacturer Hubitron Steuerungstechnik Hauptstr 4 1 89611 Obermarchtal Germany Product Alignment Calibration System ACS 1000 and Remote Con...

Страница 14: ...sanleitung ACS 1000 Rev 1 0 08 12 Hubitron Steuerungstechnik Hubitron Steuerungstechnik Hauptstr 4 1 D 89611 Obermarchtal Tel 49 0 7375 922066 FAX 49 0 7375 922077 Seite 14 von 14 Attachment Measuring...

Отзывы:

Похожие инструкции для ACS-1000