FIXTURE LENGTH
6.000
6.000
BACK VIEW
E
J
N
REMOVE LED ASSEMBLY BY REMOVING
(6) #8 SHEET METAL SCREWS
K
K
RAISE FIXTURE ONTO WALL BRACKET STUDS AND SECURE 1/4-20
NUTS FROM INSIDE. DO NOT FULLY TIGHTEN AT THIS TIME.
L
M
LOCATE WALL BOX LOCATIONS
ACCORDING TO BACK VIEW ABOVE
INSTALL END CAP ON
BEGINNING OF ROW SIDE (OR
BOTH SIDES OF INDIVIDUAL
FIXTURE) BY INSERTING WELD
STUDS INTO PROPER HOLES
(BE CAUTIOUS OF LEFT HAND
VS RIGHT HAND) AND
SECURING WITH #8-32 NUTS
PROVIDED IN END CAP KIT
(SHIPPED SEPARATELY)
IF INSTALLING A ROW, JOIN FIXTURES
TOGETHER USING SCREWS IN HARDWARE KIT.
WIRING CONNECTIONS CAN GO THROUGH
BOTTOM HOLES IN END HEADERS. TIGHTEN
WALL MOUNT BRACKET NUTS.
RE-INSTALL LED
ASSEMBLY
REPEAT STEP 3 AND INSTALL END
OF ROW END CAP
litecontrol.com
DO NOT MODIFY OR ALTER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF
YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100.
INSTALLATION INSTRUCTIONS
FIXTURE SERIES: 22L
MOUNTING TYPE: WALL
REV / DATE: 0 / 10/19/18
PAGE: 3 OF 3
DRAWING: 510688