S.M.A.R.T. E

MERGENCY 

P

HONES

42004-661L2C

f:\standard ioms - current release\42004 instr. manuals\42004-661l2c.doc
11/02

Placing a Non-Emergency Call (Models 294ALSL and 298SL Only)

The emergency phone models with keypads can also be used to make non-emergency type calls as
follows:

1.

 

Press the 

C

ALL

 push button.

2.

 

Wait for dial tone.

3.

 

Use the keypad to dial the desired number.

To disconnect the call, press the 

C

ALL

 push button a second time.

Disconnecting a Call Remotely

A call to a S.M.A.R.T. phone can be ended or disconnected (put back “on-hook”) remotely by entering
the control command 

*99

.

Installation

General Safety Guidelines

When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to
ensure the safety of all personnel:

 

NEVER install telephone wiring during a lightning storm.

 

NEVER install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.

 

NEVER touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.

 

USE CAUTION when installing or modifying telephone lines.

General Installation Guidelines

 

GAI-Tronics emergency telephones are not designed to be installed in parallel or to be “party-lined.”
Any such installation can cause programming difficulties, premature disconnection of calls, or
stations that may not respond when activated.  GAI-Tronics highly recommends that one telephone
line (PBX extension or CO line) be allocated for each unit.

 

GAI-Tronics highly recommends that a telephone line surge suppressor be installed to guard against
lightning strikes.  Please consult our Service Center at 800-523-4303 if further information is
required.

 

Install sealed fittings at all cable entry points to prevent liquids from entering the unit.

 

To ensure that the unit is vandal-resistant, GAI-Tronics recommends running the subscriber line
inside conduit and external power (if needed) in conduit.

 

GAI-Tronics recommends bottom conduit entry on all telephone installations for best results.

Содержание GAI-TRONICS S.M.A.R.T. 293ALSL

Страница 1: ...ency Call from a S M A R T Phone 2 Placing a Non Emergency Call Models 294ALSL and 298SL Only 3 Disconnecting a Call Remotely 3 Installation 3 General Safety Guidelines 3 General Installation Guidelin...

Страница 2: ...ronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party Introduction The GAI Tronics S M A R T Emergency Phones are designed...

Страница 3: ...uter and provides access to a wide range of system usage and status reports Refer to the manual provided with the TMS application software for information on available features and for remote programm...

Страница 4: ...or wet locations NEVER touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface USE CAUTION when installing or modifying telephone lines...

Страница 5: ...removing the cover to avoid dropping it 2 Disconnect the front panel from the enclosure 3 Remove the 4 clear spacer rods from the corners of the enclosure and discard 4 Four 0 28 inch holes have been...

Страница 6: ...used hole GAI Tronics recommends using silicone sealant around and inside all conduit entries and plugs See Figure 2 for details 6 Pull the telephone line through the conduit Connect the telephone lin...

Страница 7: ...Tamper Resistant Screwdriver sold separately 2 Prepare the mounting surface for installation of the back box See Figure 4 for the back box dimensions 3 Install the customer supplied telephone line sur...

Страница 8: ...ck remove the cover and connect the green and red wires of the telephone line to the green and the red wires of the modular wall jack See Figure 4 for details Replace the modular wall jack cover 8 Con...

Страница 9: ...et to a nominal level that is acceptable for most installations When speaker adjustments are necessary follow these steps 1 Loosen the 4 tamper resistant screws on the front panel using the GAI Tronic...

Страница 10: ...ernalPower An external power supply sold separately must be connected to the phone to use the relay output The power supply must provide 200 mA of current 10 V dc to 30 V dc and must be isolated from...

Страница 11: ...standard ioms current release 42004 instr manuals 42004 661l2c doc 11 02 ConnectingaBeacon Figure 7 shows a typical connection detail of the GAI Tronics 530A 530FB Beacon and Model C01009 Power Supply...

Страница 12: ...a steady pace This is important because the programming sequence times out if there is a pause of more than 2 seconds during the programming sequence Complete the following steps to enter the programm...

Страница 13: ...memory location 01 on the EEPROM Auto dial memory storage accommodates up to 24 characters 1 To enter the auto dial number into memory storage or to change the number in storage enter 101 CHAR 1 Data...

Страница 14: ...assign a time limit or change an existing time limit 50 Data transfer command 6 999 Call duration 60 9980 seconds 999 disabled See example below End of string indicator Multiply the desired time limit...

Страница 15: ...rchase order number If the equipment is under warranty repairs will be made without charge Please include a written explanation of all defects to assist our technicians in their troubleshooting effort...

Страница 16: ...State 1 Call in Trigger Disabled RTC Interrupt Sensor Disabled Dormant State 1 Call in Trigger Disabled Integrity Loop Sensor Enabled Dormant State 0 Call in Trigger Disabled Tilt Sensor Disabled Dorm...

Страница 17: ...93SL Construction Valox safety yellow Dimensions 9 5 H 8 W 4 D inches 241 3 203 2 101 6 mm Weight 4 0 lbs Model 293ALSL Construction Cast aluminum painted safety yellow Dimensions 9 5 H 8 W 4 D inches...

Отзывы: