background image

Pub.:42004-661L2C

GAI-Tronics Corporation  P.O. Box 1060, Reading, PA  19607-1060  USA

610-777-1374  

n

  800-492-1212  

n

  Fax:  610-775-6540

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ®   C O R P O R A T I O N

A   H U B B E L L   C O M P A N Y

S.M.A.R.T. Emergency Phones

Models 293SL, 293ALSL, 294ALSL, 297SL, and 298SL

T

A B L E   O F  

C

O N T E N T S

Confidentiality Notice ................................................................................................................ 1

Introduction ............................................................................................................................... 1

Operation ................................................................................................................................... 2

Placing an Emergency Call from a S.M.A.R.T. Phone ..................................................................... 2

Placing a Non-Emergency Call (Models 294ALSL and 298SL Only) .............................................. 3

Disconnecting a Call Remotely .......................................................................................................... 3

Installation................................................................................................................................. 3

General Safety Guidelines ................................................................................................................. 3

General Installation Guidelines......................................................................................................... 3

Installing a 293 or 294 Series Phone.................................................................................................. 4

Installing a 297 or 298 Series Phone.................................................................................................. 6

Speaker Volume Adjustment............................................................................................................. 8

Relay Output .............................................................................................................................. 9

External Power .............................................................................................................................................. 9
Connecting a Beacon ................................................................................................................................... 10

Programming ........................................................................................................................... 11

Enter the Programming Mode......................................................................................................... 11

Basic Programming Commands...................................................................................................... 12

Auto-dial Memory ....................................................................................................................................... 12
Call Time-out .............................................................................................................................................. 13
Line Ring Detection..................................................................................................................................... 13

Maintenance ............................................................................................................................ 14

Reference Material................................................................................................................... 14

Table R-1.  Basic Programming Commands................................................................................... 14

Table R-2.  Default Configuration................................................................................................... 14

Specifications ........................................................................................................................... 16

Содержание GAI-TRONICS S.M.A.R.T. 293ALSL

Страница 1: ...ency Call from a S M A R T Phone 2 Placing a Non Emergency Call Models 294ALSL and 298SL Only 3 Disconnecting a Call Remotely 3 Installation 3 General Safety Guidelines 3 General Installation Guidelin...

Страница 2: ...ronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party Introduction The GAI Tronics S M A R T Emergency Phones are designed...

Страница 3: ...uter and provides access to a wide range of system usage and status reports Refer to the manual provided with the TMS application software for information on available features and for remote programm...

Страница 4: ...or wet locations NEVER touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface USE CAUTION when installing or modifying telephone lines...

Страница 5: ...removing the cover to avoid dropping it 2 Disconnect the front panel from the enclosure 3 Remove the 4 clear spacer rods from the corners of the enclosure and discard 4 Four 0 28 inch holes have been...

Страница 6: ...used hole GAI Tronics recommends using silicone sealant around and inside all conduit entries and plugs See Figure 2 for details 6 Pull the telephone line through the conduit Connect the telephone lin...

Страница 7: ...Tamper Resistant Screwdriver sold separately 2 Prepare the mounting surface for installation of the back box See Figure 4 for the back box dimensions 3 Install the customer supplied telephone line sur...

Страница 8: ...ck remove the cover and connect the green and red wires of the telephone line to the green and the red wires of the modular wall jack See Figure 4 for details Replace the modular wall jack cover 8 Con...

Страница 9: ...et to a nominal level that is acceptable for most installations When speaker adjustments are necessary follow these steps 1 Loosen the 4 tamper resistant screws on the front panel using the GAI Tronic...

Страница 10: ...ernalPower An external power supply sold separately must be connected to the phone to use the relay output The power supply must provide 200 mA of current 10 V dc to 30 V dc and must be isolated from...

Страница 11: ...standard ioms current release 42004 instr manuals 42004 661l2c doc 11 02 ConnectingaBeacon Figure 7 shows a typical connection detail of the GAI Tronics 530A 530FB Beacon and Model C01009 Power Supply...

Страница 12: ...a steady pace This is important because the programming sequence times out if there is a pause of more than 2 seconds during the programming sequence Complete the following steps to enter the programm...

Страница 13: ...memory location 01 on the EEPROM Auto dial memory storage accommodates up to 24 characters 1 To enter the auto dial number into memory storage or to change the number in storage enter 101 CHAR 1 Data...

Страница 14: ...assign a time limit or change an existing time limit 50 Data transfer command 6 999 Call duration 60 9980 seconds 999 disabled See example below End of string indicator Multiply the desired time limit...

Страница 15: ...rchase order number If the equipment is under warranty repairs will be made without charge Please include a written explanation of all defects to assist our technicians in their troubleshooting effort...

Страница 16: ...State 1 Call in Trigger Disabled RTC Interrupt Sensor Disabled Dormant State 1 Call in Trigger Disabled Integrity Loop Sensor Enabled Dormant State 0 Call in Trigger Disabled Tilt Sensor Disabled Dorm...

Страница 17: ...93SL Construction Valox safety yellow Dimensions 9 5 H 8 W 4 D inches 241 3 203 2 101 6 mm Weight 4 0 lbs Model 293ALSL Construction Cast aluminum painted safety yellow Dimensions 9 5 H 8 W 4 D inches...