![Hubbell GAI-Tronics RED ALERT 393-001AD Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/hubbell/gai-tronics-red-alert-393-001ad/gai-tronics-red-alert-393-001ad_manual_2180598032.webp)
P
UB
.
42004-472C
A
UTO
-D
IAL
T
ELEPHONE
M
ANUAL
Page 30 of 34
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-472C.docx
07/16
Table 11. Programming Documentation Table
Function
Key Sequence
Default
Settings
User Settings
Auto-dial or Ring-Down Programming (see Table 3 on Page 24)
CALL
Button Auto-dial Number 1
DD
*1
None
CALL
Button Auto-dial Number 2
DD
*2
None
CALL
Button Auto-dial Number 3
DD
*3
None
Primary Dial Tone Delay
#10
NN
3 seconds
Secondary Line Dial Tone Delay
#11
NN
2 seconds
Ring-down Operation
*1
None
Password Protection Feature Programming (see Table 4 on Page 25
Password Protection
#14
NNNN
2468
Disconnect Options Programming (see Table 6 on Page 26)
Push-button Disconnect
#17
L
1 (enabled)
Call Time-out Disconnect
#12
NN
10 minutes
Dial Tone Disconnect
#19
L
0 (disabled)
ADA Programming (see Table 7 on Page 27)
DTMF Disconnect Option
#18
L
1 (enabled)
Identification Code Entry
#13
LNNN
None
Other Programming Features
Auto-Answer Alert Feature
(see Table 5 on Page 25)
#16
L
0 (disabled)
Extended Strobe Operation
(see Table 8 on Page 27)
NN
…*8
#26
NNN
90125
#26050 (5 sec.)
Output 4 Control Setup
(see Table 9 on Page 28)
#25
NNN
0 0 0 (disabled)
Early Microphone Option
(see Table 10 on Page 29)
#71
L
0 (disabled)
Table Legend
D = DTMF digit 0–9, *, or #
N = Numeric digit 0–9 L = 0-Disable, 1-Enable