Americans with Disabilities Act (ADA) Programming
The ADA features provide the following benefits:
C
ALL
R
ECEIVED
W
HEN
L
IT
indication - This lamp provides indication to hearing-impaired
individuals that the auto-dial call has been answered.
The Location Identification Code - This feature enables security personnel to quickly and easily
locate an individual in trouble.
DTMF Call Disconnect - Enables the security operator to disconnect the call by pressing ##.
Table 7. Americans with Disabilities Act (ADA) Programming
Feature
Key
Sequence
Description
Default
DTMF
Disconnect
Option
# 1 8
L
This option controls the DTMF “##” disconnect feature.
To enable, set
L
=1.
To disable, set
L
=0.
1 (Enabled)
Location
Identification
ID Setup
# 1 3
L N N N
This option enables and stores the three-digit location
identification ID number.
To enable the ID feature, set
L
=1.
To disable the ID feature,
L
=0.
Enter the three-digit location identification code in the
sequence
N N N
.
Example
: To enable the location ID feature and store the
three-digit ID code
357
, enter
#
1
3
1
3
5
7
.
To disable the location ID feature, enter
#
1
3
0
0
0
0
.
N
OTE
: The ADA options must also be enabled.
No default
setting. The
user must
complete this
step to have the
identification
code
transmitted.
Extended Strobe Operation (Requires External Power Supply)
Output 1 can be programmed for extended operation (remain closed) for up to 255 minutes (in 1-minute
increments) after the auto-dial call ends.
Table 8. Extended Strobe Operation
Feature
Key
Sequence
Description
Default
Extended
Strobe
Operation
# 2 5
N N N
Sets the duration of the activation of the Output 1 contact starting
at the end of a call. Use entries 001–255, representing 1 minute to
255 minutes in 1-minute increments.
Use 000 to disable this feature.
To set a duration of 7 minutes, enter
#
2
5
0
0
7
.
0 0 0