Pub. 42004-533F
HUBBCOM™ GSC3100/GSC4100 Dual-Port Flush-Mount Smart Controllers
Page 6 of 10
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-533F.docx
11/20
2.
Install a clamp on ferrite core around all wires (double wrap) terminating to
TB1
as close as possible
to the terminal block.
3.
Insert each wire into the correct quick release terminal (see Table 1).
Table 1. Terminal Block TB1—RTU I/O
Purpose
Pin
Label
RTU Input One Ground
1
GND
RTU Input One
2
IN1
RTU Input Two Ground
3
GND
RTU Input Two
4
IN2
RTU Output 1 +
5
OUT1+
RTU Output 1 −
6
OUT1(−)
RTU Output 2 −
7
OUT2(−)
RTU Output 2 +
8
OUT2+
RS-485 and External Speaker Connections
Terminal block
TB2
is for optional RS-485 and external speaker connections. Complete the following
steps to terminate the RS-485 and/or external speaker connections:
N
OTE
:
Smart controllers with external speakers require external 24 V dc power.
1.
Install appropriately sized ferrules onto the wire ends.
2.
Install a clamp on ferrite core around all wires (double wrap) terminating to
TB2
as close as possible
to the terminal block.
3.
Insert each wire into the correct quick release terminal (see Table 2).
Table 2. Terminal Block TB2—RS-485 and External Speaker
Purpose
Pin
Label
RS485 Ground
1
GND
RS485 B
2
RS485B
RS485 A
3
RS485A
External Speaker −
4
SPKR
−
External S
5
SPKR+
Ethernet
HUBBCOM smart controllers have dual Ethernet ports. Use the RJ45 jack furthest from the USB port to
connect to the Ethernet network. The RJ45 jack closest to the USB port can be used to connect a PC.
1.
Plug the Ethernet cable from the network into the RJ45 jack furthest from the USB port.
2.
Install a clamp on ferrite core as close as possible to the RJ45 plug.
3.
(Optional) Plug an Ethernet cable from a PC into the remaining RJ45 jack.