Pub. 42004-533F
HUBBCOM™ GSC3100/GSC4100 Dual-Port Flush-Mount Smart Controllers
Page 4 of 10
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-533F.docx
11/20
Surface Mount Installations
Use a GAI-Tronics Model 236 Series or Model 238-001 Enclosure to surface mount the HUBBCOM
smart controller:
1.
Refer to Pub. 42004-285 for the Model 236 Series or Pub. 42004-434 for the Model 238-001
backboxes to install the surface-mount enclosure (see the Reference Documents section). GAI-
Tronics publications are located on the GAI-Tronics website at
2.
Remove and discard the backbox installed on the smart controller by removing the six security screws
and washers. Retain the six security screws and washers.
3.
Complete all necessary cable terminations (see the Wiring section).
4.
Secure the smart controller to the surface-mount enclosure using the six security screws and washers
removed in Step 2.
5.
Tighten the screws to 10–12 in∙lb.
Figure 2. Flush-Mount Smart Controller Back Box Mounting Details