2.
Assign hex addresses 0–3 to type I cards. Assign hex addresses 4–7 to type II cards.
The columns in the
A
CCESS
P
ANEL
I
NTERFACES
S
UMMARY
screen display the address assigned to
the card after defining the card type. Column one corresponds to 0x0 and 0x4, column two represents
addresses 0x1 and 0x5, and so on.
3.
Click
◄B
ACK
to return to the
S
YSTEM
P
ROPERTIES
screen.
4.
Click
A
CCESS
P
ANEL
B
UTTON
T
EMPLATE
to configure the button template layout.
The button template defines the default button layout for the physical access panels in the Elemec3
system (see the Access Panel Button Configuration section).
Add Access Panels
The
A
DD
A
CCESS
P
ANEL
screen opens when an API card is first enabled or by clicking the
A
DD
A
CCESS
P
ANEL
button from the
A
CCESS
P
ANEL
I
NTERFACES
S
UMMARY
screen.
Figure 32. Add Access Panel
1.
Select the type of access panel to add and click
ADD DEVICE
.
•
The access panel appears under the API on the
A
CCESS
P
ANEL
I
NTERFACES
screen.
•
An
A
DD
A
CCESS
P
ANEL
button appears under each API after defining the first access panel for that
API.
2.
Select the
S
ET AS DEFAULT
checkbox to skip the AP selection screen if the remaining access panels
are the same type.