![Hubbell GAI-TRONICS Clean Phone 295-001F Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/hubbell/gai-tronics-clean-phone-295-001f/gai-tronics-clean-phone-295-001f_manual_2180597023.webp)
Pub. 42004-484G
Clean Phone
®
Analog Telephones
Page 20 of 26
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-484G.docx
04/19
Disconnect Options
Several options are available for disconnecting a call. Any combination of disconnect options may be
used. Select the method that best suits the application and follow the appropriate programming
directions.
Table 8. Disconnect Options
Feature
Key
Sequence
Description
Default
Call Time-out
Disconnect
Option
# 1 2
N N
This feature programs the maximum length of a call if no
other disconnect features are used. The valid entries are
1–99, representing 1-minute increments and 0
representing 4.5 hours. The call duration timer begins
when the telephone goes off-hook. The telephone
automatically disconnects after the programmed time-out
period elapses.
Example
: To make the maximum call length 2 minutes,
enter
# 1 2 0 2
.
10 (10
minutes)
Dial Tone
Disconnect
Option
# 1 9
L
N
OTE
:
Use this option only if no other disconnect
options are available.
The telephone automatically terminates a call if it detects
a dial tone continuously for 10 seconds with this option
enabled (Ex. the called party hangs up).
To enable the dial-tone disconnect,
L
=1.
To disable the dial-tone disconnect,
L
=
0
.
Example
: To enable the dial tone disconnect, enter
# 1 9
1
.
To disable the dial tone disconnect, enter
# 1 9 0
.
0 (Disabled)
N
OTE
:
Simply pressing the on/off push button will disconnect the call.
Output One Extended Control Operation
Output one can be programmed for extended operation (remain closed) for up to 255 minutes (in 1-minute
increments) after the emergency call ends.
Table 9. Extended Strobe Operation
Feature
Key
Sequence
Description
Default
Extended Strobe
Operation
# 2 5
N N N
Sets the duration of activation for output one contact
starting at the end of a call. Use entries 001–255,
representing 1 minute to 255 minutes in 1-minute
increments.
Use 000 to disable this feature.
To set a duration of 7 minutes, enter
# 2 5 0 0 7
.
0 0 0
(Disabled)