102.

 

Receiving, Moving and Storing Systems and Batteries

102.1 Shipping Damage

Inverter system batteries are shipped inside unit inside a sep

a

rate carton.

Carefully inspect all cartons upon receipt for evidence of shipping damage.
Notify carrier immediately of leaking or damaged cartons for possible concealed damage.

102.2 Temporary Storage of Units and Batteries

For temporary storage of 

LG 

inverter systems and batteries prior to installation, select a clean, cool,

 

dry location with normal ventilation for human habitation and level floors. 

Storage Temperature:

Store all batteries at 0° to +40° C (32° to +104° F). Batteries will have a longer shelf life if stores at 15°

C (60° F). The 

LG 

electronics battery cabinets may be stored at -20° to +60° C (-4° to +140° F).

 

IMPORTANT:

Lengthy storage of batteries will cause irreversible damage to the cells.
Failure to connect 

LG 

inverter system batteries to an energized charging circuit within 90 days from

 

the date of shipment will void the battery warranty.

DANGER: 

Explosive - Can Cause Blindness Or Other Severe Injuries

Every type of battery can produce hydrogen gas, even sealed, maintenance-free batteries. The gas is

 

vented through caps and into the air. 

Do not allow smoking, sparks, or flames in battery storage 

location becuase hydrogen is concentrated under the vent cap of each cell of the battery. Hydrogen

 

is highly explosive, and is hard to detect because it is colorless, ororless, and lighter than air. 

103.

 

Installation Requirements

103.1 Operating Environment

Install the 

LG 

inverter system in a clean, cool, dry place with normal ventilation for human habitation

 

and in such a location to hamper vandalism but allow easy access for testing and maintenance.

Operating Temperature:

LG 

Inverter Systems are UL Listed for 20° to 30° C (+68° to +86° F) operation.

Battery performance and service life is maximized if the operating temperature is maintained at 25°

C (77° F).

Temperature Effect On Lead Calcium Battery Performance:

Lead Calcium batteries will be less efficient at temperatures below 20° C (68° F), and high tempera-

tures will reduce battery life. Typically, at 35° C (95° F), battery life will be half of what it would be at

 

normal temperature of 25° C (77° F). At 45° C (113° F), battery life will be one-fourth of normal.

 

Ventilation:

The air around the unit must be clean, dust-free, and free of corrosive chemicals or other contami-
nants. Do not place the 

LG 

inverter system or batteries in a sealed room or container. 

103.2 High Altitude Operation:

The maximum operating temperature drops 1° Celsius per 300 meters (2° F per 1000 feet) above

 

sea level. Maximum elevation is 3000 meters (10,000 feet).

104.

 

Cabinet Mounting

104.1 Tools Required

The following tools are required to install the system:
Socket Set, Phillips Screwdriver, Diagonal Wire Cutters, Long Nose Pliers, Electrical Tape, Digital

 

Volt-Ohm Meter, Safety Glasses with Side Shields, Small Punch (knockout removal), Hammer, 
Electric Drill, Wood or Masonary Bits, Level.

5.

Содержание DUAL LITE LiteGear LG Series

Страница 1: ...Manual For LG Series For 375VA 375W 600VA 600W Large Inverter Power Systems Models LG375S Surface Mounted Version LG600S Surface Mounted Version LG375SI LG600SI Surface Mounted Version w Self Test Su...

Страница 2: ...rpose Servicing of this equipment should be performed by qualified service personnel SAVE THESE IMPORTANT SAFETY INSTRUCTIONS The installation and use of this product must comply with all national fed...

Страница 3: ...am 120Vac and 277Vac connections AC Input output Wiring Connections to Terminal Block Wiring Diagram Switched Dimming Control 120 277Vac Battery Information Tools Battery installation and Connection W...

Страница 4: ...Recharge time Meets UL requirements 96 Hours Battery protection Automatic low battery voltage disconnect and reverse polarity protection Standard batteries Sealed Lead Calcium 7 year life Battery vol...

Страница 5: ...s hard to detect because it is colorless ororless and lighter than air 103 Installation Requirements 103 1 Operating Environment Install the LG inverter system in a clean cool dry place with normal ve...

Страница 6: ...kouts provided using mounting hard ware not supplied sized appropriately to support the unit weight 105 AC Connections CAUTION A LG inverter system units contain hazardous AC and DC voltages Because o...

Страница 7: ...277Vac input connections as well as various modes of output opertion as described in this section Refer to the appropriate wiring diagrams to properly con nect the utility AC power fixtures and exter...

Страница 8: ...0 volts Load Operation Adjustable Output AO Option Functionally identical to the Switch Load Operation above but provides four 4 independent settings for each of the four dimmable loads See Wiring Dia...

Страница 9: ...R DIMMED CIRCUITS SHOWN Note ONLY 2 OF 4 POSSIBLE SWITCHED OR DIMMED CIRCUITS SHOWN See LiteGear loading table on the next page NOTE Dimming switches are designed for independent settings to allow dif...

Страница 10: ...gether or to ground earth Be extremely careful to avoid electric shock and burns caused by contacting battery terminals or shorting terminals during battery installation Do not touch uninsulated batte...

Страница 11: ...nd upwards Position batteries in the central locations towards rear of the compartments Carefully install battery retention brackets in each compartment with the supplied hardware Reference below imag...

Страница 12: ...12...

Страница 13: ...will damage the unit void the warranty and may cause a dangerous or unsafe condition 108 System Start Up Procedure IMPORTANT The LG inverter system is a sophisticated electronic backup power supply C...

Страница 14: ...d connected loads B Self testing and a 30 second discharge with a randomized start per UL 924 Sec 30 2 once every 30 days after normal utility power has been supplied for a minimum of 48 hours C Self...

Страница 15: ...warranty voided if not routinely recharged NOTE To turn power back on follow the System Start up Procedure outlined in Section 108 Be sure to complete all of the steps to ensure the unit will operate...

Страница 16: ...by the Manufacturer will void the UL listing of the system and may cause equipment failure To ensure the superior performance of your LG inverter system and to maintain proper charger operation repla...

Отзывы: