background image

5

Easy to operate: simple wiring, fool operation.

Comprehensive protection: multiple protection (over-voltage protection, over- current
protection at high and low voltage sides), rapid action (when acting)

Room ≤10ms), the instrument is safe and reliable.

Safety and reliability: the controller is connected with the low voltage of the high voltage
generator, with photoelectric control, safe and reliable use.

The high and low voltage closed-loop negative feedback control circuit is adopted,
and the output has no capacity rise effect.

Complete configuration: capacitive touch screen, LCD Chinese character display,
automatic storage, automatic printing.

Large test range: 0.1Hz, 0.05Hz and 0.02hz multi frequency selection, large test range.

Small volume and light weight: it is very convenient for outdoor operation.

Upper computer background management software

selective assembly

V. Instrument structure and function description

The instrument consists of two parts: controller and booster. The structure and function of
the two parts are as follows:

1.

The layout of each part of the controller panel is shown in Figure 1, and the function

description of each part is as follows:

Figure 1 Schematic diagram of controller panel

“ ”

Grounding terminal: it is connected with the earth when in use.

"Switch" - power switch: built-in indicator light, on when on, off when "AC220V" - power
input socket, built-in fuse.
“Printer” - print test reports.

Содержание VLF Hipot

Страница 1: ...VLF Hipot Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Страница 2: ...lease read the instruction manual carefully and keep it for reference this product is a test instrument for high voltage electrical equipment Please operate according to the operation instructions and...

Страница 3: ...gy 2 III technical parameters of series products 3 IV Product features 4 V Instrument structure and function description 5 VI Power cable withstand voltage test method 15 VII Transportation and preser...

Страница 4: ...mings of domestic similar products see table 1 and its cost performance is much higher than that of similar imported products It is especially suitable for withstand voltage test of electrical equipme...

Страница 5: ...m Commission has formulated the industry standard of ultra low frequency 0 1Hz withstand voltage test method for 35kV and below XLPE insulated power cables In 2004 the industry standard DL T 849 4 200...

Страница 6: ...5 5 F 80kV 0 1Hz 1 1 F 80KV 0 5 20A Controller 4Kg 0 05Hz 2 2 F Peak Value booster 50Kg 0 02Hz 5 5 F Compare content Power frequency withstand voltage Frequency withstand voltage 0 1Hz withstand volt...

Страница 7: ...se earth capacity of different types of generators Steam turbine generator Hydro generator Capacity MW 200 300 600 85 125 150 300 400 Single phase ground capacitance uF 0 198 0 18 0 26 0 31 0 34 0 69...

Страница 8: ...automatic storage automatic printing Large test range 0 1Hz 0 05Hz and 0 02hz multi frequency selection largetest range Small volume and light weight it is very convenient for outdoor operation Upper...

Страница 9: ...ed to communicate with the upper computer Stop for emergency stop test 2 Structure diagram of booster Figure 2 Schematic diagram of booster structure Operation instructions 1 Ultra low frequency outpu...

Страница 10: ...After the microcomputer is powered on or reset the instrument will automatically enter the interface as shown in Figure 4 When connecting wires removing wires or temporarily not using the instrument t...

Страница 11: ...ge limit it will no longer boost voltage and maintain constant amplitude sine wave output at this peak value Set voltage limit the setting range of voltage protection value is from 0 to rated value an...

Страница 12: ...not connected in the status bar of Figure 6 indicates that the booster or capacitive test sample is not connected Figure 6 the controller indicates that the load is not connected 2 Boosting process A...

Страница 13: ...ut Figure 8 constant amplitude output of controller prompt 4 Downtime When the timing reaches the set time the instrument will stop automatically as shown in Figure 9 and the prompt message in the sta...

Страница 14: ...own as shown in Figure 11 the prompt message in the status bar is test passed and the data history is saved Note during the test if there is no abnormal voltage no discharge or overcurrent protection...

Страница 15: ...ess of test when the output high pressure exceeds the set limit the instrument will automatically cut off the output after starting and shutting down the command and then execute the data history savi...

Страница 16: ...nt key in Figure 3 to print the data on the display into a test report Under the status of viewing historical data click the print key to print the historical data currently displayed on the screen 5...

Страница 17: ...to open the setting interface in Figure 15 which is used to set the date and time of the system 3 Upper computer background management software This instrument is equipped with VLF super low frequenc...

Страница 18: ...e setting value of 0 1Hz ultra low frequency test voltage of various rubber and plastic insulated power cables Table 4 0 1Hz ultra low frequency test voltage and time of various rubber plastic insulat...

Страница 19: ...ltage unit kV Example 2 a 10KV UN 10kV uo 8 7kv cable is 4km long with a single phase to ground capacitance of 0 21uf km and 0 1Hz super If the low frequency test voltage is 26kv peak value the leakag...

Страница 20: ...quired to turn on and power on once a month about two hours to make the moisture emission and protect the components 4 anti exposure When the instrument is used outdoors direct sunlight exposure shall...

Страница 21: ...ke the printing paper stretch out from the paper outlet put it in the middle position and let the rubber shaft fully press the printing paper otherwise it can t be printed When the thermal printer is...

Страница 22: ...19 X Packing List No Name Qty 1 Controller 1 2 Booster 1 3 HV Cable 2 4 LV Cable 1 5 Power Cable 1 6 Discharge Rod 1 7 Grounding Wire 1 8 Capacitor 1 9 Fuse 4 10 Print Paper 2...

Отзывы: