7
channel selection is CH1(CH2).
2) Setting: Press” setting” F2 key to activate the current channel setting options.
Output voltage:
Set output voltage for the sensors of the equipment which is to be
tested.
Press “ output voltage” F1 key to open the output voltage, press F1 key once to close
the voltage. When open the output voltage, the light will be on at the display screen.
When close the output voltage, the light will be off at the display screen.
Unit:
Switch the measurement unit of the current channel discharge amount, mv,
dB,dbmW, dBuV, dBmV.
Press “ Unit” F2 key to change the current channel discharge Unit, This option is circular
selection, the unit selection can be determined by the discharge detection type.
Reading set, discharge numbers and sensors: Keep them as default values,
non-professionals are forbidden to make any change.
Traffic light: Change the current channel traffic light, The color can be changed per
requirement.
Press Traffic light F2 key to activate traffic light color setting menu, traffic light colors are
green, yellow, red. Double press keys to change color.
If change to “ Green”, double press green” F1” key, then make change by pressing
arrow keys at the pop-up dialog box.