6
Mode(3)
The mode key is used to select the receiver's operating mode for precise positioning of
the pipeline. The positioning process is usually measured by the peak method.
Including:
Valley mode
Peak mode
Wide mode
Peak arrow mode
Power mode: 50Hz power cable can be detected
When there is an external A-frame, you can also select the external signal mode.
(4)
To increase, please press
To decrease, please press
.
In the adjustment, the number is shown in the middle of the display window.
Press
or
for 3 seconds to start the function automatically. The number turns into
flashing cursor(as shown on the left), the instrument automatically adjusts the Signal
strength to about 70% of full scale. The relative intensity of the signal is indicated by the