7
bar graph(8) above the display window and the number(9) below the graph.
Depth/Current
(
5
)
key is used to measure the depth of the buried pipeline, meanwhile it could
measurethe current value in the target line. In the current measurement process,
regardless of the original use of which positioning mode, the system automatically
switches to the peak mode.
The depth measurement unit can be selected by metric or imperial from the menu.
Metric Units: cm when the depth of the pipeline is less than 1 meter.
When the depth is more than 1 meter, the depth display unit is m.
Inch unit: feet.
Current unit: When the current is more than 1A, the display current unit is A, when the
current is less than 1A, the display current unit is mA.
Note:
1, in order to measure the exact depth of the depth, the receiver must be
maintained in the vertical position of the work.
2, in order to improve the accuracy of the depth of the measurement, it is not
suggested to use the valley mode, the wide-peak mode is recommended for
pipeline depth measurement.