4 Spatter

Spatter can cause fire or explosion.

Remove fire hazards from the welding area. Remember that spatter from welding can easily go

through small cracks and touch fire hazards. Protect all kinds of lines going though welding area, including hydraulic
lines in the wild.

Where compressed gases are to be used in the field, special precautions should be used to prevent explosion.

When welding stops, make certain that no live part is touching the work piece or the work stage. Accidental

contact can create a fire hazard.

Do not weld containers or lines, which are not proved to be innocuous.

It is very dangerous to heat, cut or weld tanks or containers at entry holes. Does not start work until the proper

steps have been taken to insure that there is no flammable or toxic gas.

Spatter might cause burn. Wear leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair

to prevent from burning by spatter. Wear the ear shield when performing sideways or face up welding. Always wear
safety glasses with side shields when being in a welding area.

The welding cables should be as close to the welding area as possible, and the short, the better. Avoid welding

cables going through the building framework, lifting chains, AC or DC cables of other welding machines and
appliances. The welding current is strong enough to damage them while having short circuit with them.

5 Cylinder

Damage of it might cause explosion.

Make sure that the gas in the storage cylinder is qualified for welding, and the decompression

flow-meter, the adapter and the pipe are all in good condition.

Make sure that the installation of cylinder is by the wall and bundled tightly by a chain.

Be sure to put the cylinder in the working space with no crash or shake, and far from welding area.

It is forbidden to touch cylinder with the welding clamp or the work cables.

Avoid facing the cylinder while installing the decompression flow-meter or the gasometer.

When not working, please tighten the valve.

6 Power

(For electrically powered welding and cutting equipment) Turn off input power before

installation, maintenances and repair, so that avoid accident.

HUAYUAN welding equipment is Ι class safeguard equipment; please install the equipment in accordance with

the manufacturer’s recommendations by specific persons.

Ground the equipment perfectly in accordance with the manufacturer’s recommendations.

7 Power

(For engine driven welding and cutting equipment)

Work in ventilated place or outdoors.

Do not add fuel near to fire or during engine starting or welding. When not working, add fuel after engine is cooling
down; otherwise, the evaporation of hot fuel would result in dangers. Do not splash fuel out of the fuel tank, and do
not start the engine until complete evaporation of the outside fuel.

Содержание LGK-63/100MA

Страница 1: ...LGK 63 100MA IGBT INVETER AIR PLASMA CUTTING MACHINE OPERATOR S MANUAL PLEASE READ IT CAREFULLY BEFORE OPERATION info westweld com...

Страница 2: ...eld rank of this series of cutter is IP21S so working in rain is not suitable 4 The cutter has external static characteristic with rated duty cycle 60 which means the machine can work 6 minutes and re...

Страница 3: ...lectrode holder the grounding clamp the welding cable and the welding head are not affected by damp mildewed or spoilt and be replaced momentarily Never dip the electrode in water for cooling Never to...

Страница 4: ...les of other welding machines and appliances The welding current is strong enough to damage them while having short circuit with them 5 Cylinder Damage of it might cause explosion Make sure that the g...

Страница 5: ...tirely your body with the cable c Do not place yourself between the welding cable and the ground work piece cable if the welding cable is by your left side then the ground cable should be by your left...

Страница 6: ...TS Summary 6 Safety and Attention 6 Work Environment Requirements 7 Technical Parameters 7 Working Principles 8 Panel and Functions 9 Installation and Operation 10 Maintenance 13 Cutting Technology In...

Страница 7: ...anufacturing of boiler pressure container chemical container industrial power station construction metallurgy aerospace industry automobiles building and other metal cutting fields Safety and Attentio...

Страница 8: ...ign bodies entering into the cutting power Cutting power should be 30cm away from the wall or other sealed in objects The distance between two sets should be above 30cm The operation height should be...

Страница 9: ...The real time cutting current which is obtained through current sensor connected to output terminal in series is used as negative feedback control signal After comparing with current adjusting signal...

Страница 10: ...n control board LGK4063IGBT AP1 LGK 40 63IGBT LGK60T AP1 LGK 100IGBT 10 AP3 HF board LGK7 63AP3 11 AP5 Filter board LGK63IGBT AP5 12 Air filter regulator GFR 200 08 Diagram Common component list Panel...

Страница 11: ...minal It is gas pipe connector to connect water cooled torch when the water cooled torch is used and it is connector to connect torch air cooled cable when air cooled torch is used 9 Power source swit...

Страница 12: ...oint Plasma gas conditions Connect the gas pipe with the gas inlet of air filter on the back panel and hoop it tightly The usage of air filter regulator is as follows When it is to adjust pressure lif...

Страница 13: ...cutting please loosen the torch switch cutting arc extinguishes and gas supply will stop in 5 8S automatically Notes Operation strictly accordant with the following steps Notice Electric shock may hur...

Страница 14: ...y Maintenance The cutter cannot be operated and placed in strong sunshine The cutter cannot be operated and placed in moist environment The vent hole should not be covered when the cutter is operated...

Страница 15: ...g speed is too slow but the incision bottom is so over heated that it melts the liquid metal flows to bottom metal and combines into one which makes the difficulty to blow away molten metal by air cur...

Страница 16: ...are not ON 1 Three phase power misses phase 2 Supply power is damaged 3 Power control fuse 1 5A is broken 1 Check three phase power source 2 Change power switch 3 Change power control fuse 2 Supply a...

Страница 17: ...du Huayuan Electric Equipment Co Ltd LGK 40 63 100IGBT OPERATOR S MANUAL 16 Accessories 1 Cutting power source 1set 2 Cutting torch 1pc 3 Ground cable 1pc 4 Product certificate 1pc 5 Instruction manua...

Страница 18: ......

Отзывы: