First confirm the installation location of the guide rail in the cabinet. Install the floating nuts used to fix the 
guide rail in the installation location. There are two and three floating nuts at the front and rear of the 
cabinet respectively, as shown in the lower left figure.

1

2

For details about how to install floating nuts, see the lower right figure. As shown in step 1 in the 
lower-right figure, insert one leg of the floating nut into the square holefrom inside of the cabinet, 
so that the leg hooks over the lower frame of the square hole. Asshown in step 2 in the lower-right 
figure, use the floating nut hook to catch the other leg of thefloating nut. Pull the hook forward until 
the leg hooks over the upper frame of the square hole.
 

5.3 Cabinet Installation

5

5.3.1 Single-Device Deployment Scenario

Note:
     Before installing the VCN520 or VCN540 in the cabinet,  install the mapping guide rail to bear the 
     device.  If a guide rail has been installed in the cabinet, check whether the guide rail matches the 
     device. The device is equipped with right-to-left airflow. Therefore, check whether the guide rail 
     may block the air exhaust vent. If yes, replace the guide rail with a matched one. 
     Huawei provides the guide rail for the VCN. The stretching range of the guide rail ranges from 
     500 mm to 800 mm, which is used for cabinet installation when the distance between the front and 
     rear mounting bars is within the range. You need to purchase the guide rail based on the site 
     requirements. 
     When the VCN is installed in a cabinet, do not install the rubber foot which will occupy the cabinet 
     space.

1U

Front of the cabinet

Rear of the cabinet

2

Install the guide rail. Horizontally place the guide rail to the installation location through the positioning block 
at the front of the guide rail and the positioning hook at the rear of the guide rail, as shown in the lower left 
figure. Use four M6 screws (two on each side) to fix the front end and six M6 screws (three on each side) 
to fix the rear end, as shown in the lower right figure.

3

Front of the cabinet

Rear of the cabinet

Note: Before installing the guide rail, you can view the mark (F/L, F/R) on the guide rail to differentiate 
the left, right, front, rear ends of the guide rail to avoid reverse installation. F/L indicates the front end 
of the guide rail on the left side. F/R indicates the front end of the guide rail on the right side.

Positioning
block

Positioning 
hook

1

Содержание VCN520

Страница 1: ...nom d utilisateur mot de passe de connexion par défaut du client C S IP accesso predefinito nome utente password C S client 192 168 2 101 Admin Change_Me Default login URL user name password of the OMU Portal URL nom d utilisateur mot de passe de connexion par défaut du portail OMU URL accesso predefinito nome utente password Portale OMU https 192 168 2 101 8443 Admin Change_Me BOM 31508624 ...

Страница 2: ...ION Disconnect the power cord before serving to avoid electric shock Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Double pole neutral fusing NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are...

Страница 3: ...INK indicator Disk status indicator Power health indicator GE port LINK indicator Disk status indicator Front view of VCN540 Specification Description Networking performance A maximum of 16 VCN520 VCN540 in a stack Media performance A VCN520 VCN540 supports access from cameras that comply with the HWSDK ONVIF or DHSDK protocol A VCN520 supports 32 channel cameras the ingress bandwidth does not exc...

Страница 4: ...ce Audio input interface GE2 port Power button Power port COM port KB interface RS 485 interface Rear view of VCN540 Ground terminal Alarm input interface Alarm output interface GE1 port USB2 0 USB3 0 VGA port HDMI port Audio output interface Audio input interface GE2 port Power button Power port COM port KB interface RS 485 interface Note The VCN520 or VCN540 has two USB interfaces USB2 0 and USB...

Страница 5: ...tep 2 in the following figure 1 Note By default the VCN520 or VCN540 does not carry disks when being delivered First install disks and then install the device on the desktop or in a cabinet After the VCN520 or VCN540 is delivered to the site disk filler panels are installed in slots where disks are not installed by default You are not advised to remove the filler panels from the slots where disks ...

Страница 6: ... may block the air exhaust vent If yes replace the guide rail with a matched one Huawei provides the guide rail for the VCN The stretching range of the guide rail ranges from 500 mm to 800 mm which is used for cabinet installation when the distance between the front and rear mounting bars is within the range You need to purchase the guide rail based on the site requirements When the VCN is install...

Страница 7: ...llips screwdriver to fasten the screws to fix the mounting ears as shown in the following figure Install the filler panel of the guide rail Install the M6 screws used to fix the filler panel of the guide rail as shown in the following figure 5 Install the floating nuts used to fix the VCN520 VCN540 The floating nuts are installed in the first and sixth holes along the guide rail from bottom to up ...

Страница 8: ... configure each mounting ear Separately secure the mounting ears on both sides of the subrack on the mounting bar at the front of the cabinet as shown in the lower right figure 7 5 3 2 Multi Device Deployment Scenario Note When multiple VCN520s or VCN540s are deployed a guide rail needs to be installed for each device A VCN520 or VCN540 requires 2 U space A guide rail requires 1 U space Therefore ...

Страница 9: ...rew uses M4 screws The PGND cable is prepared by the customer The PGND cable is green and yellow and its diameter must range from 16 AWG to 18 AWG The GE ports on a device are bonded in load balancing mode by default You can use two network cables to connect the two GE ports to a switch the two ports on the switch connected to the network cables require link aggregation or you can connect any one ...

Страница 10: ...device Optional To use audio device such as headsets and speakers insert the cable terminal of an alarm input device into the alarm input port Ensure that the alarm input device and VCN are both grounded Optional To use alarm output devices such as alarm bells insert the cable terminal of an alarm output device into the alarm output port Insert one end of the power cable to the power supply interf...

Страница 11: ...nks once every 2s The system is being started Blinking at a frequency of 1 Hz blinks once every second A component other than the disk is faulty Blinking at a frequency of 5 Hz blinks once every 0 2s The disk is faulty Off The network port is improperly connected Steady on The network port is properly connected Steady on The hard disk is properly connected Blinking The hard disk is transmitting da...

Страница 12: ...NK indicator GE1 and GE2 Off The board is not powered on Steady on The system is running properly Blinking at a frequency of 0 5 Hz blinks once every 2s The system is being started Blinking at a frequency of 1 Hz blinks once every second A component other than the disk is faulty Blinking at a frequency of 5 Hz blinks once every 0 2s The disk is faulty Off The network port is improperly connected S...

Страница 13: ...documentation from the Huawei enterprise service website Visit http support huawei com enterprise choose Support Intelligent Video Surveillance Cloud Intelligent Video Surveillance VCN520 VCN540 V100R002C30 and download the desired documents For details about configuration see the Configuration Guide in the VCN510 VCN520 VCN540 V100R002C30 product documentation 11 Open Source Software Notice Log i...

Страница 14: ...64 〇 indicates that the content of the hazardous substance contained in all of the homogenous materials for the component is below the limit specified in GB T 26572 indicates that the content of the hazardous substance contained in at least one of the homogenous materials for the component is above the limit specified in GB T 26572 Printed circuit board as semblies PCBAs Capacitors Other electroni...

Страница 15: ...hipment Notes 1 When you purchase a product from Huawei please confirm the date when the product will be shipped from Huawei and check other warranty related information 2 For expansion and replacement parts you are entitled to either of the following warranties whichever is longer 1 A 90 day warranty starting from the date the replacement parts are shipped 2 The remaining warranty of the original...

Отзывы: