![Huawei V300R001 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/huawei/v300r001/v300r001_parts-replacement_168100043.webp)
l
Label
Procedure
Step 1
Perform a pre-replacement check.
Check whether there is a redundant power module and whether the Running/Alarm indicator
of the redundant power module is steady green, as shown in
. For details about
the indicators on different components, see
Running/Alarm Indicators on a Data Switch
.
Figure 4-33
Running/Alarm indicator on a power module
You can perform replacement only when a redundant power module exists and the redundant
power module is working properly.
Step 2
Wear an ESD wrist strap.
Step 3
Press the latch on the power module to release the handle and pull out the power module, as
shown in
Figure 4-34
Removing a power module
Step 4
Put the removed power module into an ESD bag.
OceanStor Dorado V3 Series
Parts Replacement
4 Replacing CRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.
35