![Huawei V300R001 Скачать руководство пользователя страница 206](http://html.mh-extra.com/html/huawei/v300r001/v300r001_parts-replacement_168100206.webp)
Figure 5-120
Installing a disk module
3.
Ensure that the ejector lever is fastened to the chassis beam, and lower the ejector lever
to completely insert the spare part into the chassis. See step (2) in
Step 3
Wait until the disk indicator lights up, indicating that the spare part is powered on.
----End
Follow-up Procedure
Log in to the quorum server.
1.
Run the
qsadmin
command to check whether the configuration page of the quorum
server software is displayed.
Q2qumrom:~ # qsadmin
start main!
Waiting for connecting to server...
admin:/>
–
If the preceding command output is displayed, go to
–
If the preceding command output is not displayed, the configuration information
about the quorum server software has been lost. In this case, reinstall and configure
the quorum server software.
NOTE
BC&DR Solution Product Documentation (Active-Active DCs)
.
2.
Run the
show server_ip
command to check whether the connections between the
quorum server and storage devices are in
Established
state.
admin:/>show server_ip
Index Server IP Server Port
----- --------------- ---------------
1 192.168.6.31 30002
2 192.168.7.31 30002
Index Local IP Local Port Remote IP Remote
Port State
OceanStor Dorado V3 Series
Parts Replacement
5 Replacing FRUs
Issue 05 (2019-01-30)
Copyright © Huawei Technologies Co., Ltd.
198