HUAWEI TP3206&TP3218&TP3218S Telepresence
Installation Guide
9 Installing Devices
Issue 05 (2014-08-01)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
102
Step 2
Loosen the screws in the left and right sides of the cabinet door and remove the door.
----End
Follow-up Procedure
After the telepresence system is installed and commissioned, check whether the
multi-functional conference table is stable. If it is not stable, adjust the foot bolts in the
equipment cabinet until the cabinet withstands the multi-functional conference table, and
install the cabinet door.
9.2.4 Installing PDUs
Background
The telepresence system provides six power distribution units (PDUs). Their installation
locations are shown in
and
. Their functions are listed in the following:
PDU 1: 7-outlet PDU, installed on the right rack and used to supply power to the three
codecs.
PDU 2: 5-outlet PDU, installed on the center rack and used to supply power to the left
and right subordinate speakers.
PDU 3: 5-outlet PDU, installed on the left rack and used to supply power to the wireless
router.
PDU 4: 5-outlet PDU, installed in the equipment cabinet and used to supply power to the
main speaker.
PDU 5: 7-outlet PDU, installed on the center rack and used to supply power to the three
HD displays.
PDU 6: 5-outlet PDU, installed in the equipment cabinet and used to supply power to the
multi-functional sockets.
Procedure
Step 1
Attach mounting ears to PDUs 2, 3, 4, and 6 and install the PDUs on the corresponding
locations on the racks. Install the remaining PDUs in the equipment cabinet.
Step 2
Vertically install the PDUs on the racks, with one side outwards, as shown in