Item
SUN2000-1
25KTL-M0
SUN2000-1
10KTL-M0
SUN2000-1
00KTL-M0
SUN2000-1
00KTL-M1
SUN2000-1
00KTL-
INM0
SUN2000-7
5KTL-M1
Minimum
startup
voltage
200 V
Full-load
MPPT
voltage
range
625–850 V
540–800 V
540–800 V
540–800 V
(380 V/400
V) and
625–850 V
(480 V)
540–800 V
(415 V)
625–850 V
(480 V)
540–800 V
(380 V/400
V) and
625–850 V
(480 V)
Rated input
voltage
750 V
600 V
600 V
570 V (380
V), 600 V
(400 V),
and 720 V
(480 V)
620 V (415
V) and 720
V (480 V)
600 V (380
V/400 V),
720 V (480
V)
Maximum
short-circuit
current (per
MPPT)
40 A
Maximum
backfeed
current to
the PV
array
0 A
Number of
inputs
20
Number of
MPP
trackers
10
Note a: The maximum input voltage is the upper threshold of the DC voltage. If the input voltage
exceeds the threshold, the solar inverter may be damaged.
Note b: If the input voltage is beyond the operating voltage range, the solar inverter cannot work
properly.
Output
Item
SUN2000-1
25KTL-M0
SUN2000-1
10KTL-M0
SUN2000-1
00KTL-M0
SUN2000-1
00KTL-M1
SUN2000-1
00KTL-
INM0
SUN2000-7
5KTL-M1
Rated
active
power
125 kW
110 kW
100 kW
100 kW
100 kW
75 kW
SUN2000-(75KTL, 100KTL, 110KTL, 125KTL) Series
User Manual
10 Technical Specifications
Issue 11 (2021-11-10)
Copyright © Huawei Technologies Co., Ltd.