RRU3832&RRU3632
Installation Guide
3 Information About the Installation
Issue 05 (2014-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
21
Figure 3-18
RU installed on angle steel
Installing an RU on a Wall
The wall for installing RUs must meet the following requirements:
For each RU, the wall must be able to bear a weight four times the RU's weight and the
bolts' pulling force of 1.25 kN (281.25 lbf) vertical to the wall.
Expansion anchor bolts must be tightened to 30 N·m (265.52 lbf·in.) so that the bolts
stay secured without damaging the wall.
It is recommended that the RU be installed on a wall in standard mode.
When RUs are installed on a wall in side-mounted mode, do not combine mounting
brackets for multiple RUs, as shown in
Figure 3-19
Correct installation of mounting brackets for multiple RUs installed on a wall in
side-mounted mode