Installing an RRU on a Pole
shows the diameter of a pole for installing an RRU.
Figure 3-7
Diameter of a pole
NOTICE
l
The diameter of a pole for installing an RRU ranges from 60 mm (2.36 in.) to 114 mm (4.49
in.). The recommended diameter is 80 mm (3.15 in.).
l
When the diameter of a pole ranges from 60 mm (2.36 in.) to 76 mm (2.99 in.), a maximum
of three RRUs can be installed on the pole and the side-mounted installation is recommended.
The RRU installation in standard mode is not recommended.
l
Only a pole whose diameter ranges from 76 mm (2.99 in.) to 114 mm (4.49 in.) supports
more than three RRUs.
l
The recommended thickness of the pole wall is 3.5 mm (0.14 in.) or above.
shows a single RRU installed on a pole.
3 Information About the Installation
Issue ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.