Figure 7-19
Opening clips
----End
7.10 Installing an RRU power cable
This section describes the procedure for installing an RRU power cable.
Prerequisite
l
An easy power receptacle (pressfit type) connector is added to the RRU power cable on
the RRU side. For details, see
10.1 Adding an Easy Power Receptacle (Pressfit Type)
Connector to the RRU Power Cable on the RRU Side
l
A connector or OT terminals are added to the RRU power cable on the power device side.
For details, see the
DBS3900 Installation Guide
.
Context
The cross-sectional area of the RRU power cable is 6 mm
2
(0.009 in.
2
).
Procedure
l
Install an RRU power cable that feeds power to an RRU from a DCDU-11B when the
DCDU-11B is configured.
1.
Link the easy power receptacle (pressfit type) connector at one end of the RRU power
cable to the power supply socket on the RRU, as shown in
.
RRU3942
Installation Guide
7 Installing RRU Cables
Issue ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
77