Figure 3-8
Minimal space requirements of one RRU3804 with and without the SRXU (unit:
mm)
The minimal space around the equipment is as follows:
l
300 mm under the equipment for cabling. It is recommended that the space is 1,200 mm
between the bottom and the ground for easy maintenance.
l
600 mm in front of the equipment for maintenance.
l
200 mm above the equipment for maintenance.
l
400 mm on the left of the equipment for maintenance.
l
100 mm on the right of the equipment for maintenance.
When two RRU3804s need to be combined, the space between the two RRU3804s should stay
within the range shown in
Figure 3-9
.
Figure 3-9
Space requirements of two combined RRU3804s (unit: mm)
3 Installing RRU3804 and SRXU Hardware
RRU3804
User Guide
3-8
Huawei Technologies Proprietary
Issue 01 (2007-11-29)