Huawei PI-DC A11 Скачать руководство пользователя страница 3

Principles and Application  Scenarios

Product Overview

The  RTN  PI-DC  A11 receives  one  channel  of DC  power  signals and  one channel  of  GE service  signals.
The  signal  coupling  module  couples DC  power  signals and  GE service  signals into P&E signals and outputs the P&E signals 
to the P&E port.
The  frequencies  of DC  power  signals and  GE service  signals do  not interfere  with each  other. Therefore,  the two types of 
signals can be transmitted  over  the same twisted pair.

DC-DC 

processing 

mode

DC  IN

Signal 

coupling 

module

GE

P&E

DC-PI  working principles

DC-PI

powered 
device

UNI-side 
device

≤ 100 m

•The PI only couples GE signals and power signals, but does not regenerate or strengthen GE signals. Therefore, the 
network cable between the UNI-side device and the powered device must not be longer than 100 m.
•The maximum distance between the PI and the powered device varies depending on the power of the powered device. 
For details, see technical specifications.

Maximum 

distance between 

the PI and 

powered  device

CAUTION

B

Application Scenarios

A

Principles

Mapping between powered device types and power supply  modes

03

The  RTN  PI-DC  A11 can supply power  to OptiX RTN  300  full-outdoor  microwave  equipment  series. The  power  supply 
mode  of the PI  varies  according  to powered  device  type.

Device Type

Version

PI Support 

(Yes/No)

Power Supply Mode

RTN  310  (Integrated)

SHXA2  board

Yes

Turn  the DIP  switch to the Force  mode.

SXA3  board

Yes

Turn  the DIP  switch to the PSE-PD mode.

RTN  310 (Split)

Yes

Turn  the DIP  switch to the PSE-PD mode.

RTN  320  (Integrated)

No

N/A

RTN  320  (Split)

No

N/A

RTN  320F

No

N/A

RTN  360  (V-band)

Yes

Turn  the DIP  switch to the PSE-PD mode.

RTN  380  (E-band)

SHUF3  board

Yes

Turn  the DIP  switch to the Force  mode.

MXUF4  board

Yes

Turn  the DIP  switch to the PSE-PD mode.

RTN  380e

Yes

Turn  the DIP  switch to the PSE-PD mode.

RTN  380A

Yes

Turn  the DIP  switch to the PSE-PD mode.

RTN  380AX

No

N/A

RTN  380H

MXUI5  board

No

N/A

MXXI5  board

No

N/A

Содержание PI-DC A11

Страница 1: ...es Co Ltd Copyright Huawei Technologies Co Ltd 2018 All rights reserved 01 Safety Precautions Always hold an insulated part of the P E cable Never touch the RJ45 connector Do not touch the pins inside the P E port on the PI with your hands or a conductor Be sure to connect the power cables of the PI correctly to the positive and negative terminals of the power supply device To prevent damage to po...

Страница 2: ...B Port Description The GE electrical port is compatible with an FE electrical port and supports the MDI MDI X and auto MDI MDI X modes Pin Description 1 BGND 2 BGND 3 48 V power signal 4 BGND 5 BGND 6 48 V power signal 7 48 V power signal 8 48 V power signal Whether the P E ports use MDI or MDI X mode to transmit Ethernet service signals does not affect the pin assignments for power signals Pin as...

Страница 3: ...ending on the power of the powered device For details see technical specifications Maximum distance between the PI and powered device CAUTION B Application Scenarios A Principles Mapping between powered device types and power supply modes 03 The RTN PI DC A11 can supply power to OptiX RTN 300 full outdoor microwave equipment series The power supply mode of the PI varies according to powered device...

Страница 4: ...Compliant with ETSI EN 301 489 4 Compliant with ETSI EN 300 386 Safety Passes CE certification Compliant with EN60950 22 Compliant with IEC60950 22 Compliant with IEC60950 1 Compliant with EN60950 1 Item Description Major reference standards Operation Compliant with EN 300 019 1 4 class 4 1 Transportation Compliant with ETSI EN 300 019 1 2 class 2 3 Storage Compliant with ETSI EN 300 019 1 1 class...

Страница 5: ...d outside the holes remove the cable and cut the wires Then strip and connect the cable again A line mustbe inserted in the center of a hole A line mustbe perpendicular to a hole A line mustbe inserted in the center of a hole 4 CAUTION Insert the power cable Hole 2 Inserta blue 48 V line into it Hole 1 Inserta brown black 0 V ground line into it Ensure that the positive and negative lines are corr...

Страница 6: ...s in an ETSI cabinet adjust the holes for installing mounting ears based on the cabinet type 3 0 0 3 N M M6 2 0 0 2 N M M6 NOTE NOTE Installing the PI in a 19 Inch Cabinet Insert the PI into a slot on the auxiliary mounting bracket and tighten the captive screws on the mounting ears 1 2 Fix the floating nuts 3 4 Install the chassis in the cabinet Install the PGND cable Insert the PI into a slot on...

Страница 7: ...g ears 1 3 4 Install the PI on the wall Install the PGND cable 2 Mark and drill holes in the wall Hold the PI up to the wall and mark the drilling positions Drill the holes and insert the fixing bolts The position of the holes should allow a heat dissipation space of at least 50 mm at both the top and bottom of the PI 8 Drilling positions Drill Ф8 holes to a depth of 52 to 60 mm 300mm Mounting ear...

Страница 8: ... NOTE Connect the RJ45 connector to the GE port of the PI Black 0 V power cable connected to the positive terminal of the power supply device Install the P E cable of the PI Install the power cable of the PI Power on the device 1 Turn the power output switch on the rear of the PI to the FORCE side 2 Switch on the power supply device connected to the PI NOTE In normal conditions DC IN and P E OUT i...

Отзывы: