Paramete
r
Description
Value
Default
Retention
If no expiration time is configured for a
file, the expiration time of the file is
determined by the default retention.
[Value range]
No less than
Min.
Retention
and no bigger
than
Max. Retention
or
Indefinite
.
[Default value]
Regulatory compliance
Mode:70 years
Enterprise compliance
Mode:3 years
NOTE
To set
Default Retention
as
Indefinite
, you must set
Max.
Retention
to
Indefinite
.
Otherwise, the setting fails.
Automatic
Lock
If the function is enabled and a file is file
is not modified within the
Lockout Wait
Time (hours)
, files enters locked state
automatically. Therefore, the file is under
protection, and you can only read the file
under locked state, but cannot modify,
delete or rename it.
NOTE
Write operation include file data change or
metadata change.
[Default value]
Enable
Lockout
Wait Time
(hours)
Retention of a file enters the locked state.
NOTE
This parameter is valid only when
Automatic
Lock
is enabled.
[Value range]
The value is an integer
ranging from 2 to 168.
[Default value]
2
Automatic
ally
Delete
If this mode is enabled, the system
automatically deletes files whose
protection period is overdue.
[Default value]
Disabled
NOTE
– If WORM is enabled, the file system created is a WORM file system. More information about
WORM file system, see
OceanStor V3 Series V300R006 WORM Feature Guide
.
– Before creating a WORM file system, you must initialize WORM regulatory clock through
CLI. The CLI command is
change system secure_compliance_clock date=?
.
3.
Click
OK
.
The
Create File System
dialog box is displayed.
Step 7
Confirm that you want to create this file system.
OceanStor V3 Series
HyperMetro Feature Guide for File
4 Configuration
Issue 05 (2018-01-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
109