Item
Description
Heat dissipation
13289.74 BTU/hour
DC input
voltage
Rated
voltage
-48 V
Maximum
voltage
range
-38 V to -72 V
AC input
voltage
Maximum
voltage
range
90 V to 275 V AC
175 V to 275 V AC(recommend)
System
reliability
MTBF
(year)
36.23
MTTR
(hour)
0.5
Ambient
temperature
Long-term
0°C to 45°C (32°F to 113°F)
Short-term
-5°C to 55°C (23°F to 131°F)
Remarks
Limit of the temperature change rate: 30°C (86°F)/hour
Storage temperature
-40°C to 70°C (-40°F to 158°F)
Relative
humidity
Long-term
5% RH to 85% RH, no coagulation
Short-term
5% RH to 95% RH, no coagulation
Storage humidity
5% RH to 100% RH, no coagulation
Long-term altitude
≤
4000 m (If the altitude is between 1800 meters and 4000
meters, the operating temperature of the device must decrease
by 1°C for every 220 meters increase in altitude.
NOTE
As shown in the table, "width" does not involve the dimensions of rack-mounting ears.
As shown in the table, "width" does not involve the dimensions of rack-mounting ears. The measurement point
of the temperature and humidity is 1.5 m (4.92 ft) over the floor and 0.4 m (1.31 ft) in front of the cabinet without
the front and back doors.
Short-term operation means that continuous operating time does not exceed 48 hours and accumulated operating
time per year does not exceed 15 days. If an operation exceeds either of these conditions, it is called a long-term
operation.
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description