RRU3606 CDMA Base Station Product Description
Commercial in Confidence
Page 39 of 43
Air pressure
70 kPa–106 kPa
Temperature
–40
o
C to +70
o
C
Temperature change rate
3
o
C/min
Relative humidity
5%–100%
Solar radiation
1,120 W/s²
Heat radiation
600 W/s²
Wind speed
50 m/s
II. Waterproof Requirements
Before transporting the equipment, make sure that:
The package is intact.
Waterproof measures are applied to prevent water penetration.
No water accumulates in the vehicle.
III. Biological Requirements
Ensure that the vehicle is free of:
Fungus or mildew
Rodents such as rats
IV. Air Purity Requirements
The air should be free from explosive, conductive, magnetic conductive or corrosive
dust.
The density of physically active materials must comply with the requirements listed in
Table 7-19.
Table 7-19
Requirements for physically active materials in transportation environment
Physically active material
Unit
Density
Suspending dust
mg/m³
35
Falling dust
mg/m²·h
0.2
Sands
mg/m³
30
Note:
Suspending dust: diameter 75
3
m
Falling dust: 75
3
m diameter 150
3
m
Sands: 150
3
m diameter 1,000
3
m
The density of chemically active materials must comply with the requirements listed in
Table 7-20.