Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
bfd
cfg-name
bind
peer-ip
peer-ip
[
vpn-instance
vpn-instance-name
]
interface
interface-type
interface-number
[
source-ip
source-ip
]
one-arm-echo
A BFD session with the one-arm Echo function is created.
NOTE
l
A BFD session with the one-arm Echo function can detect only single-hop links.
l
A BFD session currently does not detect route switching. If the change of bound peer IP address causes
a route to switch to another link, the BFD session is negotiated again only when the original link fails.
Step 3
Run:
discriminator
local
discr-value
The discriminator is set for the BFD session that one-arm Echo function configured.
The one-arm Echo function can be configured only on the BFD-capable device at one end of a
link. A BFD session with this function must be configured with a local discriminator rather than
a remote discriminator.
Step 4
(Optional) Run:
min-echo-rx-interval
interval
The minimum interval between receipt of BFD packets is set.
By default, the minimum interval between receipt of BFD packets is 10 milliseconds.
Step 5
Run:
commit
The configuration is committed.
NOTE
After configuring the local discriminator parameter and any other required parameters for a BFD session
with the one-arm Echo function, you must run the
commit
command to make the configuration take effect.
----End
3.6.4 Checking the Configuration
By viewing the type and status of a BFD session with the one-arm Echo function, you can check
whether the configurations are correct.
Prerequisite
The configurations of the one-arm Echo function are complete.
Huawei AR2200-S Series Enterprise Routers
Configuration Guide - Reliability
3 BFD Configuration
Issue 01 (2012-01-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
156