6 Technical Specifications of the DBS3900
Airbridge DBS3900 CDMA Base Station
Product Description
6-14
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 11 (2010-06-18)
z
The concentration of mechanically active substances complies with the requirements
listed in
Table 6-19
.
Table 6-21
Requirements for the concentration of mechanically active substances in the storage
environment of the equipment
Concentration
Mechanically
Active Substance
Unit
BBU
RRU
Suspended dust
mg/m
3
≤
5
≤
5
Precipitable dust
mg/m
2
·h
≤
20
≤
500
Grit mg/m
3
≤
300
≤
300
NOTE
z
The diameter of a suspended dust particle is not greater than 75 µm.
z
The diameter of a precipitable dust particle is not smaller than 75 µm and not greater than 150 µm.
z
The diameter of a piece of grit is not smaller than 150 µm and not greater than 1000 µm.
z
The concentration of chemically active substances complies with the requirements listed
in
Table 6-20
.
Table 6-22
Requirements for the concentration of chemically active substances in the storage
environment of the equipment
Chemically Active
Substance
Unit
Concentration
SO
2
mg/m
3
≤
0.30
H
2
S mg/m
3
≤
0.10
NO
2
mg/m
3
BBU:
≤
0.50
RRU:
≤
0.05
NH
3
mg/m
3
≤
1.00
Cl
2
mg/m
3
≤
0.10
HCl mg/m
3
≤
0.10
HF mg/m
3
≤
0.01
O
3
mg/m
3
≤
0.05
Mechanical Stress Requirements
Table 6-21
and
Table 6-22
list the requirements for the mechanical stress in the storage
environment of the equipment.