2 Solutions for the Auxiliary Devices of the DBS3900
Airbridge DBS3900 CDMA Base Station
Product Description
2-4
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 11 (2010-06-18)
Figure 2-2
Indoor distributed installation
Auxiliary Device
Table 2-2
lists the auxiliary devices used in the indoor distributed installation of the
DBS3900.
Table 2-2
Auxiliary devices used in the door distributed installation of the DBS3900
Component
Description
Indoor centralized
installation rack or L-shaped
support
The indoor centralized installation rack or L-shaped support
is used for the BBU3900 and RRU3606 respectively. The
indoor centralized installation rack can be installed on the
ground, on a wall, or in a piled way. The L-shaped support
can be installed on the ground.
DCDU
The DCDU is a DC power distribution box and supports one
-48 V power input and multiple -48 V outputs.
z
If the distance between the RRU3606 and the BBU3900 exceeds 70 m [229.66 ft], independent
power supply equipment needs to be configured for the RRU3606.
z
The auxiliary devices should be configured according to the actual situation in the equipment room.
2.3 Outdoor Centralized Installation of the DBS3900
This describes the outdoor centralized installation of the DBS3900. In this mode, the major
modules are the BBU3900 and RRU3606. The BBU3900 supports 220/110 V AC and -48 V
DC power input. The DC RRU3606 supports -48 V DC power input. The AC RRU3606