Airbridge DBS3900 CDMA Base Station
Product Description
6 Technical Specifications of the DBS3900
Issue 11 (2010-06-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6-9
Item
Specification
Ambient temperature for
running
-40°C [-40°F] to +52°C [125.6°F] (solar radiation not
considered)
Relative humidity for
running
5% RH to 100% RH
6.3 Reliability Specifications of the DBS3900
This describes the reliability specifications of the DBS3900.
Table 6-16
lists the reliability specifications of the DBS3900.
Table 6-18
Reliability specifications of the DBS3900
Item
Specification
Availability
≥
99.999%
Mean Time Between Failures (MTBF)
BBU3900:
≥
280000 hours
RRU3606:
≥
260000 hours
Mean Time To Repair (MTTR)
≤
1 hour (excluding the time needed
for the engineers to arrive at the site)
≤
3 hours (including the time needed
for the engineers to arrive at the site)
6.4 Lightning Protection Specifications of the DBS3900
This describes the lightning protection specifications of the DBS3900 in terms of lightning
specifications of the power input port, E1/T1 input port, GPS RF signal input port, dry contact
port, and RF antenna port.
Table 6-17
lists the lightning protection specifications of the DBS3900.
Table 6-19
Lightning protection specifications of the DBS3900
Item
Specification
AC power input port
Differential mode: ±60 kA, 8/20 us
Common mode: ±60 kA, 8/20 us
DC power input port
Differential mode: ±2kA, 1.2/50 us
Common mode: ±4kA, 1.2/50 us