background image

6

7

IDENTIFICATION  OF  PARTS

Power Cord and plug

Continuous drain hose outlet

Power cord buckle (placed in the water bucket,
used only when storing the unit. Installed as 
shown Fig.3a))

Front

Rear

Caster

Identification of par ts

Fig.2

Fig.3

Control panel

1

2

3

4

5

1

2

3

4

NOTE:

 

All the pictures in the manual are 

for explanation purposes only. The actual 
shape of the unit you purchased may be 
slightly different, but the operations and 
functions are the same.
             

OPERATING  THE  UNIT

W hen using the unit

 When first using the dehumidifier, operate the unit
 continuously 24 hours. Make sure the plastic cover on
 the continuous drain hose outlet install stightly properly
 so there are no leaks. 

This unit is designed to operate with a working 

O

O

O

O

environment between 5 C/41 F and 35 C/95 F.
If the unit has been switched off and needs to be 
switched on again quickly, allow approximately
three minutes for the correct operation to resume.
Do not connect the dehumidifier to a multiple socket 
outlet, which is also being used for other electrical 
appliances.
Select a suitable location, making sure you have easy 
access to an electrical outlet.
Plug the unit into a  electrical socket-outlet with earth 
connection.
Make sure the Water bucket is correctly fitted otherwise 
the unit will not operate properly.

NOTE:

When the water in the bucket reaches to a certain 

level,please be careful to move the machine to avoid it 
falling down.

Casters(At four points on the bottom of unit)
    

Casters can  move freely.

    Do not force casters to move over carpet, 
    nor move the unit with water in the bucket.
    (The unit may tip over and spill water.)

 A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed
 storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

20cm or more

20cm or more

40cm or more

20cm or more

40cm or 
more

Positioning the unit

 Do not use outdoors.
 This dehumidifer is intended for indoor residential 
 applications only. This dehumidifier should not be used
 for commercial or industrial applications.
 Place the dehumidifier on a smooth, level floor strong
 enough to support the unit with a full bucket of water.
 Allow at least 20cm of air space on all sides of the unit
 for good air circulation (at least 40cm of air space on
 air outlet).
 Place the unit in an area where the temperature will not
 fall below 5 C(41 F). The coils can become covered with 
 frost at temperatures below 5 C(41 F), which may reduce
 performance.
 Place the unit away from the clothes dryer, heater or radiator.
 Use the unit to prevent moisture damage anywhere books
 or valuables are stored.
 Use the dehumidifier in a basement to help prevent 
  moisture damage.
 The dehumidifier must be operated in an enclosed
 area to be most effective.
 Close all doors, windows and other outside openings
 to the room.

Fig.4a

Accessories:(placed in the water bucket of the unit)

pump drain hose(1pc) (only for the unit with pump featrue)                          

power cord buckle(1pc)                  female threaded end(1pc)(on some models)

Pump drain hose outlet(some models without)

5

1

3

4

5

2

1

2

3

5

4

6

7

Panel

Water bucket

Water level window

Handle (both sides)

6

7

Air outlet grille

Air filter 

Insert the power cord buckle
into the unit.

Fig.3a

Air outlet grille

Содержание X6PW

Страница 1: ...OWNER S MANUAL DESHUMIDIFIER X6PW HTWDB40X6PW HTWDB50X6PW Thanks for choose our product Please read carefully this manual before use the product ENGLISH...

Страница 2: ...erly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troublesho...

Страница 3: ...Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take sp...

Страница 4: ...Up Down pads to set the Auto start and Auto stop time from 0 0 to 24 The humidity level can be set within a range of 35 RH Relative Humidity to 85 RH Relative Humidity in 5 increments For drier air pr...

Страница 5: ...over carpet nor move the unit with water in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storag...

Страница 6: ...hen the continuous draining feature is not being used remove the drain hose from the outlet and dry the water in the continuous drain hose outlet Fig 7 Fig 8 Pump hose drops Reinstall pump hose proper...

Страница 7: ...pump Check the pump hose does not link or block Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull fi...

Страница 8: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com www htwspain com...

Отзывы: