CONTROL  PADS  ON  THE  DEHUMIDIFIER

NOTE:

 The control panel of the unit you purchased may be slightly different according to the 

models. 

CONTROL  PADS  ON  THE  DEHUMIDIFIER

Other features 

Bucket Full Light

Glows when the bucket  is ready to be 
emptied.

When frost builds up on the evaporator coils, the 
compressor will cycle off and the fan will continue 
to run until the frost disappears.

Auto Defrost

Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restart 
opertation in the first 3 minutes. This is to protect 
the unit. Operation will automatically start after 
3 minutes.

Setting the Timer

 When the unit is on, first  press the Timer 
 button,  the Timer Off indicator light 
 illuminates. It indicates the Auto Stop 
 program is initiated. Press it again the 
 Time On indecator light illuminates.It 
 indicates the Auto Start is initiated.
 When the unit is off, first  press the Timer 
 button, the TIMER ON indicator light 
 illuminates. It indicates the Auto Start 
 program is initiated. Press it again the 
 Time Off indecator light illuminates.It 
 indicates the Auto Stop is initiated.
 Press or hold the UP or DOWN pad to 
 change the Auto time by 0.5 hour incre-
 ments,  up to 10 hours, then at 1 hour 
 increments up to 24 hours. The control  
 will count down the time remaining until 
 start. 
 The selected time will register in 5 seconds 
 and the system will automatically revert 
 back to display the previous humidity 
 setting.
 When the Auto start & Auto stop times are
 set, within the same program sequence, 
 TIMER ON OFF indicator lights illuminate 
  identifying both ON and OFF times are
  now programmed.
 Turning the unit ON or OFF at any time or 
 adjusting the timer setting to 0.0 will cancel
 the Auto Start/Stop function.
 When LED display window displays the
 code of  P2, the Auto Start/Stop function 
 will also be cancelled.

Check filter feature

The system starts to count the time once the fan 
motor operates. The check filter feature can be 
only activated when the accumulated operation 
time achieves 250 hours or more. The Reset 
 light(Clean filter indicator light) flashes at one time 
per second, after finishing clean the air filter, press 
the Filter pad and the Reset light(Clean filter indicator
light) goes off.  

Auto Shut Off

The 

 shuts off  when the bucket  is 

full, or when the bucket is removed or not replaced 
in the proper position.When the setting humidity is 
reached, the unit will be shut off automatically. 
For some models,the fan motor will continue 
operating.

dehumidifier

Auto-Restart

If the unit breaks off unexpectedly due to the power cut, 
it will restart with the previous function setting automa-
tically when the power resumes.

Control pads

When you push the button to change
operation modes, the unit will make 
a beep sound to indicate that it is 
changing modes.

Humidity Set Control Pads

7

: Up/Down Pads

TIMER Set Control Pads

Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.

The humidity level can be set within a range of 
35%RH(Relative Humidity) to 85%RH(Relative 
Humidity) in 5% increments.
For drier air, press the      pad and set to a lower 
percent value(%). 
For damper air, press the      pad and set  a higher 
percent value(%).

6

Timer Pad

Press to initiate the Auto start and Auto stop feature, 
in conjuction with the       and         key pads.

1

PUMP Pad(on some models)

8

Power Pad

Press to turn the dehumidifier on and off.

Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed
into the unit and the continuous drain hose is removed
from the unit before the pump operation is activated.
When the bucket is full,the pump starts to work.Refer 
to the next pages for removing the collected water. 
Do not use this operation when the outdoor temperature

O

O

is equel to or less than 0 C (32 F).
 

2

 COMFORT Pad(optional)

Press to activate the comfort 

dehumidifying operation.

NOTE: On this operation,the unit can not be set 
humidity level. 

3

 FILTER Pad

The check filter feature is a reminder to clean the 
Air Filter for more efficient operation. The Filter 
light(Clean filter l ight) will illuminate after 250 hours 
of operation. To reset after cleaning the filter, press 
the Filter pad and the light will go off.

4

 CONTINUE Pad

Press to activate the c

ontinuous dehumidifying operation.

5

TURBO Pad

Control the fan speed. Press to select either High 
or Normal fan speed. Set the fan control to High for  
maximum moisture removal. When the humidity has 
been reduced and quiet operation is preferred, set 
the fan control to Normal.

9

Display

Shows the set % humidity level from 35% to 85% or auto 
start/stop time (0~24) while setting, then shows the actual
(

±

5% accuracy) room % humidity level in a range of 

RH(Relative Humidity) to 90%RH(Relative Humidity).

Error Codes and Protection Code:
AS

- Humidity sensor error--Unplug the unit and plug it back

in. If error repeats, call for service.

ES

- Tube Temperature sensor of the evaporator error-- Unplug 

the unit and plug it back in. If error repeats, call for service.

P2

- Bucket is full or bucket is not in right position-- Empty 

the bucket and replace it in the right position.(only available for
the uint with no pump feature.)

P2

- Bucket is full -- Empty the bucket.(only available for the 

unit with pump feature.)

30%

EC

- Refrigerant leakage detection-- With this new technology,

the display area will appear   EC   when the unit detects 
refrigerant leakage ,call for service.

E3

- Unit malfunction-- Unplug the unit and plug it back in. If 

      error repeats, call for service.

Eb

- Bucket is removed or not in right position-- Replace the 

       bucket in the right position.(only available for the unit with
       pump feature.)

Fig.1a

High fan 
indicator light

On

Off

Full

3

Clean filter
indicator light 

Continuous
operation on
indicator light

Timer on/off
indicator light

1

2

Auto defrost

4

5

6

7

8

9

Auto defrost operation 
on indicator light

Bucket full
indicator light

Comfort dehumidifying
operation on 
indicator light

Pump operation 
on indicator light

Fig.1b

On

Off

Full

Defrost

Содержание X6PW

Страница 1: ...OWNER S MANUAL DESHUMIDIFIER X6PW HTWDB40X6PW HTWDB50X6PW Thanks for choose our product Please read carefully this manual before use the product ENGLISH...

Страница 2: ...erly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troublesho...

Страница 3: ...Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take sp...

Страница 4: ...Up Down pads to set the Auto start and Auto stop time from 0 0 to 24 The humidity level can be set within a range of 35 RH Relative Humidity to 85 RH Relative Humidity in 5 increments For drier air pr...

Страница 5: ...over carpet nor move the unit with water in the bucket The unit may tip over and spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storag...

Страница 6: ...hen the continuous draining feature is not being used remove the drain hose from the outlet and dry the water in the continuous drain hose outlet Fig 7 Fig 8 Pump hose drops Reinstall pump hose proper...

Страница 7: ...pump Check the pump hose does not link or block Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull fi...

Страница 8: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com www htwspain com...

Отзывы: