26
1. Avoid installing the indoor unit in a place
where generated or leaked inflammable
gas will stay.
2. Avoid installing the indoor unit in a moist
place or in a place where oil may be
splashed on the unit.
3. Select a location where outlet air may
reach each corner of the room.
4. Select a location where connection pipe
can be led to outdoor conveniently.
outlet won't be blocked.
outdoor air.
and installation.
ement of installation dimension diagram.
surroundings of a laundry a bath a
shower or a swimming pool.
5. Select a location where air inlet and
6. Select a location with least affection of
7. Select a location with firm and flat floor.
8. Retain sufficient space for maintenance
9. Ensure the installation meets the requir-
10. Do not use the unit in the immediate
Tools for installation
Selection of installation location
1 Level meter
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
14 Measuring tape
Note:
● Please contact the local agent for installation.
● Don't use unqualified power cord.
Basic requirements
Outdoor unit
Indoor unit
Installing the unit in the following pla-
ces may cause malfunction. If it is u-
navoidable, please consult the local
dealer:
vapors, flammable or explosive gas,
1. The place near strong heat sources
or volatile objects spread in the air.
2. The place with high-frequency dev-
ices (such as welding machine,
medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circums-
tances.
7. Please try your best to keep way
from fluorescent lamp.
will not affect neighborhood.
be exposed directly to sunlight or strong wind.
sion diagram.
or plants. If it is unavoidable, please add fence for safety purpose.
2. The location should be well ventilated and dry, in which the outdoor unit won't
1. Select a location where the noise and outflow air emitted by the outdoor unit
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation dimen-
5. Select a location which is out of reach for children and far away from animals
5m. The length of connection pipe should be within 10m.
6. The height difference between indoor unit and outdoor unit should be within