You have just purchased a device from HTS. Thank you for placing your trust in us. Our technically
advanced products will only function correctly if
•
their use has been carefully planned
•
they are mounted and connected in accordance with the operating instructions
•
they are put into operation in accordance with the specified instructions
•
the user is familiar with the functioning of the device.
We hereby confirm that the CE symbol has been used by HTS in pursuant to the EN 50 081-1,
EN 50 082-1 and EN 60 669 guidelines.
IMPORTANT
Do not open the device. The device does not contain
any components that can be maintained by the customer.
The warranty is no longer valid if the device is opened.
Contents
1
Safety
2
Function and performance characteristics
3
Mounting and connecting the device
4
Applications
5
Putting the device into operation
6
Warranty
7
Copyright
8
Troubleshooting
9
Technical data (rear of instruction manual)
17 Safety
Danger
All work on the 230 V power supply must be performed by authorized trained per-
sonnel only. Incorrect handling of the device can lead to serious injury or cause
damage to the ECO-IR.
Always disconnect the power supply before mounting/dismounting the ECO-IR.
The national and local specifications for handling electrical equipment must al-
ways be observed.
Read the operating instructions carefully before mounting or putting the ECO-IR into
operation.
ECO-IR presence detectors may only be used indoors
(system of protection IP 40).
The sensors must be secured firmly with the safety locking device after the upper part has
been connected (Fig. 3).
18 Function and performance characteristics
18.1 Presence detection
High-sensitivity PIR sensors and an intelligent lens system provide complete coverage.
18.2 Integrated daylight measurement
Measures the exact amount of daylight independently of the artificial lighting conditions. The
measurement is performed in the viewing direction of the device. Delayed response to
brightness changes to prevent unnecessary activation/deactivation.
18.3 "Light" switching contact
The switching contact closes if the brightness level is too low
and
if the presence of a person
is detected. It opens if the brightness level is adequate
or
if no presence is detected. The
switch-off delay time and desired switching value can be defined as required.
Important
The ECO-IR is designed for use in combination with fluorescent lamps (FL operates with
standard ballasts) and energy saving lamps (PL). When using normal incandescent or halo-
gen lamps the daylight measuring is restricted (ask supplier).
EN - 1
EN - 2