Dielectric unions or galvanized steel fittings must not be used in a 

system with this water heater. Doing so WILL VOID the warranty. It 

is recommended to use only copper, brass, or stainless steel fittings. 

Teflon thread sealant and pipe sealing compound must be used on 

all connections.

A. Plumbing

It is mandatory that all plumbing be done in accordance with federal, 

local, and state plumbing codes and practices. Failure to properly 

install the water heater WILL VOID the warranty. It is also necessary to 

use both thread tape and pipe sealing compound on all mechanical 

plumbing connections.

It is recommended to use unions on the hot and cold water connections 

to easily disconnect the water heater for servicing.

Part 3 - Piping

1. Install a shut-off  or check valve or both on the inlet connection on 

the top of the heater. Connect the cold water supply line to the shut-

off valve or check valve. Refer to piping Applications, this manual.

Do not apply heat to the Hot or Cold water heater connections. If 

sweat connections are used, sweat tubing to the adapter before 

fitting adapter to the water connections on the heater. Any heat 

applied to the water heater connections will permanently damage 

the dip tube and/or heat traps. Damages due to improper installation 

practices ARE NOT covered by warranty.

B. Thermal Expansion

2. Connect the hot water line to the connection marked “HOT” on the 

top of the water heater.

3. Install the T&P Valve in the opening provided near the top of the 

heater.

4. Install drain valve in the opening provided near the bottom of the 

heater.

A check valve may be installed in the cold water inlet line as a separate 

backflow preventer, or may be part of a pressure reducing valve, water 

meter, or water softener. An “

open water system

” refers to a system 

without a check valve. A “

closed water system

” refers to a system with 

a check valve installed in the cold water inlet line.

As water is heated, it expands in volume and increases pressure within 

the water system. This action is referred to as “

thermal expansion

”. In 

an open water system, expanding water which exceeds the capacity 

of the system flows back into the city main where pressure is easily 

dissipated.

A closed water system prevents expanding water from flowing back 

to the city main. The resulting thermal expansion can rapidly increase 

pressure in the water heater and system piping. This rapid pressure 

increase can exceed the setting of the pressure relief valve, causing it to 

operate during each heating cycle, resulting in discharge from the T&P. 

This rapid and repeated expansion and contraction of components 

in the system can cause premature failure of system components, 

including the relief valve and possibly the water heater. Replacing the 

relief valve 

will not 

correct thermal expansion.

A potable hot water expansion tank is required to offset thermal 

expansion. Expansion tanks are designed with an air cushion built 

in that compresses as system pressure increases, thereby relieving 

the overpressure condition and eliminating repeated operation of 

the relief valve. This expansion tank should be installed in the cold 

water line between the water heater and check valve, and must be 

sized for the entire water volume of the hot water system. See piping 

Applications.

Other methods of controlling thermal expansion are available. 

Check 

with the local water utility to determine if a check valve exists in 

the cold water inlet line.

 Contact your installing contractor, water 

supplier, or plumbing inspector for additional information regarding 

thermal expansion.

C. Condensation

Condensation can form on the water heater when it is first filled with 

water, and may also occur with a heavy water draw and very cold inlet 

water temperature. This condition is not unusual and will disappear 

as the water becomes heated. However, if the condensation should 

continue, examine the piping and fittings for possible leaks.

D. Insulation Blankets

If local codes require external application of insulation blanket 

kits, the manufacturer’s instructions included with the kit must be 

carefully followed.

In addition, pay careful attention to the following so as not to 

restrict the proper function and operation of the water heater:

• 

Do not cover the operating or warning labels attached to 

the water heater or attempt to locate them on the exterior 

of the insulation blanket.

• 

Do not apply insulation to the top of the water heater. This 

could interfere with the safe operation of the electrical 

junction box.

• 

Do not cover the jacket access panel(s) to the thermostat 

and heating elements or T&P valve.

• 

Inspect the insulation blanket frequently.

Failure to follow these instructions could result in property 

damage, severe personal injury, or death.

E. Temperature and Pressure Relief Valve

For protection against excessive pressures and temperatures in this 

water heater, install temperature and pressure protective equipment 

as required by local codes, but not less than a  combination T&P 

valve meeting the requirements for 

Relief Valves and Automatic Gas 

Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22B / CSA 4.4-

M99

 by a nationally recognized testing laboratory that maintains 

periodic inspection of production listed equipment and materials. 

This valve must be marked with a maximum set pressure not to 

exceed the marked maximum working pressure of the water heater. 

Install the T&P valve into the opening provided and marked for this 

purpose on the water heater. The T&P valve must be plumbed down 

so discharge can exit at least 6” above the structural floor. The relief 

line cannot be in contact with any live electrical parts.

Содержание C2X045H

Страница 1: ...sult in substantial property damage severe personal injury or death The manufacturer reserves the right to make product changes or updates without notice and will not be held liable for typographical...

Страница 2: ...er is approved for indoor installations only and is not intended for use as a pool heater Clearance to combustible materials 0 top bottom sides and back Heater must have room for service 24 front 6 to...

Страница 3: ...stems are poisonous if consumed and can cause personal injury or death NOTE Obey all local codes Obtain all applicable permits before installing the water heater NOTE Install all system components and...

Страница 4: ...luenced by proximity to damp and salty marine environments In such areas higher concentration levels of chlorides from sea spray coupled with relative humidity can lead to degradation of water heater...

Страница 5: ...ith litmus paper or have it chemically analyzed by a local water treatment company If the pH is not between 6 5 and 8 5 consult a local water treatment company for solutions NOTE If you do not provide...

Страница 6: ...110oF 43 3 C 170oF 76 6 C 190oF 87 8 C EVG100C2X045H 100 7 1 4 61 27 52 30 3 4 210 EVG115C2X045H 115 69 60 228 Table 2 Specifications and Dimensions Refers to Electrical Specifications See Table 3 for...

Страница 7: ...s in Figure 3 for the electric water heater to operate properly Please use Teflon thread tape and pipe sealing compound to seal fittings into the tank Failure to install these fittings properly will r...

Страница 8: ...and possibly the water heater Replacing the relief valve will not correct thermal expansion A potable hot water expansion tank is required to offset thermal expansion Expansion tanks are designed with...

Страница 9: ...tain appliances such as dishwashers and automatic clothes washers may require increased water temperatures By setting the thermostat on this heater to obtain the increased water temperature required b...

Страница 10: ...f inputs and amperage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the water heater Consult your electrician or a qualified techni...

Страница 11: ...lp 608 Rev 000 Rel 001 Date 3 15 18 11 Figure 5 Unlocking the Lower Element Figure 6 Water Heater and Control Wiring...

Страница 12: ...t be investigated by a qualified service technician and corrective action must be taken BEFORE placing the water heater back in service Failure to do so could result in property damage severe personal...

Страница 13: ...ent knob Turning the knob to the right clockwise raises water temperature Turning the knob to the left counterclockwise lowers water temperature Failure to disconnect the power from the water heater b...

Страница 14: ...on to the water heater Failure to refill the tank before restoring power to the water heater will result in damage to the heating elements and property damage Such damages ARE NOT covered by warranty...

Страница 15: ...age from contact with hot water Before operating lever check to see that a discharge line is connected to the valve directing the flow of hot water from the valve to a proper place of disposal Replace...

Страница 16: ...g tightly against mounting plate Ensure that retaining spring s or mounting screws hold thermostat tightly to mounting plates Thermostat setting too high or low Change setting as required Utility Cont...

Страница 17: ...lp 608 Rev 000 Rel 001 Date 3 15 18 17 Figure 10 Replacement Parts Staged Operation Part 9 Replacement Parts...

Страница 18: ...Owner that repair replacement or refund are the exclusive remedies of the Owner H HTP will not accept claims from the Owner for labor costs incurred by any person as a result of the repair replacement...

Страница 19: ...roducts a picture of the venting including how it exits the building All claims will be reviewed by HTP within three 3 business days If additional information is required and requested by the HTP Clai...

Страница 20: ...allation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please on...

Отзывы: