Water drained from the water heater may be scalding hot. Take 

care to avoid scalding. Wear gloves and safety glasses, and direct 

water to a safe drainage location. It is recommended to turn 

power off to the water heater and run water at a hot water faucet 

until it cools BEFORE draining water from the heater. Failure to 

comply with this warning could result in property damage, severe 

personal injury, or death.

The maintenance activities described below are only to be 

performed by the 

Installer / Qualified Service Provider

. These 

maintenance items should be performed during recommended 

annual

 service and any service calls.

1. Ask the owner / user if there have been any issues with the water 

heater. Diagnose any heater issues and repair / replace parts as 

necessary.

2. Check the water heater and related plumbing for leaks. Repair any 

that are found.

3. Check the area around the water heater for flammable liquids or 

combustible materials. If any are found, remove from the area.

4. Check the heating elements while the heater is in operation. If 

the elements are hissing / singing excessively, they may need to be 

cleaned. Inspect the elements and clean if necessary.

5. Inspect the Temperature and Pressure (T&P) Relief Valve. See 

instructions below.

6. Turn power supply off to the water heater. Open the drain valve 

and drain a few gallons of water from the tank to clear any hard 

water deposits. Once complete, close the drain valve and restore 

power to the water heater.

T&P Relief Valve Maintenance Instructions:

• 

Annually: 

Certain naturally occuring mineral deposits may 

adhere to the valve, blocking waterways and rendering the 

valve inoperative. The T&P Relief Valve lever must be operated 

to ensure the waterways are clear. If waterways are clear, hot 

water will discharge from the valve. Take precautions to avoid 

personal injury and property damage from contact with hot 

water. Before operating lever, check to see that a discharge 

line is connected to the valve, directing the flow of hot water 

from the valve to a proper place of disposal.

• 

Replacement of the valve is required if no water flows when 

the lever is operated. Turn the water heater off until the valve 

is replaced.

• 

If water flows from the valve, drain a few gallons from the tank 

to ensure the water flows freely.

• 

At least once every three years:

 To ensure that the T&P 

valve has not been affected by corrosive water conditions 

and that the valve and discharge line have not been altered 

or tampered with illegally, relief valves should be inspected, 

and replaced, if necessary, by a licensed plumbing contractor 

or qualified service technician.

Failure to comply with these guidelines could result in failure 

of relief valve operation,  and possibly result in substantial 

property damage, severe personal injury, or death.

Periodically (At least twice a year)

Check around the water heater and related plumbing for leaks. If 

the combination temperature and pressure relief valve discharges 

periodically, or water is leaking from around the heating elements, 

there may be a problem with your water system. DO NOT ATTEMPT 

TO REPAIR LEAKS YOURSELF! Contact a qualified service contractor 

for assistance.

Check the area around the water heater for flammable liquids or 

combustible materials. If any are found, remove from the area.

Vacation (Extended shut-off periods)

During extended mild or warm weather periods when hot water will 

not be in use, shut off the electric power to the tank. When hot water 

is needed again, restore power to the water heater.

During extended cold weather periods when hot water will not be 

in use and prone to freezing conditions, shut off electric power to 

the tank, close the supply line shut-off valve, open the drain valve 

and drain the water heater to a safe drainage location (as detailed 

previously). Once drained, close the drain valve. When hot water is 

needed again, restore the water supply to the tank. Once the tank is 

full, restore power.

Содержание C2X045H

Страница 1: ...sult in substantial property damage severe personal injury or death The manufacturer reserves the right to make product changes or updates without notice and will not be held liable for typographical...

Страница 2: ...er is approved for indoor installations only and is not intended for use as a pool heater Clearance to combustible materials 0 top bottom sides and back Heater must have room for service 24 front 6 to...

Страница 3: ...stems are poisonous if consumed and can cause personal injury or death NOTE Obey all local codes Obtain all applicable permits before installing the water heater NOTE Install all system components and...

Страница 4: ...luenced by proximity to damp and salty marine environments In such areas higher concentration levels of chlorides from sea spray coupled with relative humidity can lead to degradation of water heater...

Страница 5: ...ith litmus paper or have it chemically analyzed by a local water treatment company If the pH is not between 6 5 and 8 5 consult a local water treatment company for solutions NOTE If you do not provide...

Страница 6: ...110oF 43 3 C 170oF 76 6 C 190oF 87 8 C EVG100C2X045H 100 7 1 4 61 27 52 30 3 4 210 EVG115C2X045H 115 69 60 228 Table 2 Specifications and Dimensions Refers to Electrical Specifications See Table 3 for...

Страница 7: ...s in Figure 3 for the electric water heater to operate properly Please use Teflon thread tape and pipe sealing compound to seal fittings into the tank Failure to install these fittings properly will r...

Страница 8: ...and possibly the water heater Replacing the relief valve will not correct thermal expansion A potable hot water expansion tank is required to offset thermal expansion Expansion tanks are designed with...

Страница 9: ...tain appliances such as dishwashers and automatic clothes washers may require increased water temperatures By setting the thermostat on this heater to obtain the increased water temperature required b...

Страница 10: ...f inputs and amperage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the water heater Consult your electrician or a qualified techni...

Страница 11: ...lp 608 Rev 000 Rel 001 Date 3 15 18 11 Figure 5 Unlocking the Lower Element Figure 6 Water Heater and Control Wiring...

Страница 12: ...t be investigated by a qualified service technician and corrective action must be taken BEFORE placing the water heater back in service Failure to do so could result in property damage severe personal...

Страница 13: ...ent knob Turning the knob to the right clockwise raises water temperature Turning the knob to the left counterclockwise lowers water temperature Failure to disconnect the power from the water heater b...

Страница 14: ...on to the water heater Failure to refill the tank before restoring power to the water heater will result in damage to the heating elements and property damage Such damages ARE NOT covered by warranty...

Страница 15: ...age from contact with hot water Before operating lever check to see that a discharge line is connected to the valve directing the flow of hot water from the valve to a proper place of disposal Replace...

Страница 16: ...g tightly against mounting plate Ensure that retaining spring s or mounting screws hold thermostat tightly to mounting plates Thermostat setting too high or low Change setting as required Utility Cont...

Страница 17: ...lp 608 Rev 000 Rel 001 Date 3 15 18 17 Figure 10 Replacement Parts Staged Operation Part 9 Replacement Parts...

Страница 18: ...Owner that repair replacement or refund are the exclusive remedies of the Owner H HTP will not accept claims from the Owner for labor costs incurred by any person as a result of the repair replacement...

Страница 19: ...roducts a picture of the venting including how it exits the building All claims will be reviewed by HTP within three 3 business days If additional information is required and requested by the HTP Clai...

Страница 20: ...allation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please on...

Отзывы: