lp-608 Rev. 000 Rel. 001 Date 3.15.18
4
Part 2 - Prepare the Water Heater
COLD WEATHER HANDLING
- If the water heater has been stored
in a very cold location (BELOW 0
o
F) before installation, handle with
care until the components come to room temperature. Failure to do
so could result in damage to the water heater.
Remove all sides of the shipping crate to allow the heater to be moved
into its installation location.
A. What’s in the Box
Components included with the water heater:
•
Drain Valve
•
Temperature and Pressure Relief Valve
•
Hot Outlet Heat Trap
•
Cold Water Inlet Fitting with Dip Tube
•
Use and Care Manual and Warranty
NOTE:
Some components may ship factory installed.
All water heaters eventually leak. Locate the water heater
where any leakage from the relief valve, related piping, tank, or
connections will not result in damage to surrounding areas or
lower floors of the building. The water heater should be located
near a floor drain or installed in a drain pan. Leakage damages ARE
NOT covered by warranty.
This water heater is certified for indoor use only. DO NOT INSTALL
OUTDOORS. Outdoor installations ARE NOT covered by warranty.
Failure to install the water heater indoors could result in property
damage, severe personal injury, or death.
B. Locating the Water Heater
1. Installation Area (Mechanical Room) Operating Conditions
•
Ensure ambient temperatures are higher than 32
o
F / 0
o
C and
lower than 104
o
F / 40
o
C
•
Avoid continuously high levels of humidity
•
Never close existing ventilation openings
NOTE:
When installing in a zero clearance location, it may not be
The service life of the water heater’s exposed metallic surfaces,
such as the junction box, is directly influenced by proximity
to damp and salty marine environments. In such areas higher
concentration levels of chlorides from sea spray coupled with
relative humidity can lead to degradation of water heater
components.
2. Choose a location for the water heater as centralized to the piping
and electrical system as possible. Also, locate the water heater and
domestic water piping where it will not be exposed to freezing
temperatures. All piping should be insulated. Additionally, place the
water heater so that the drain, controls, and inlets/outlets are easily
accessible.
Figure 1 - Recommended Service Clearances - NOTE: Overhead View Not
Representative of All Models
Incorrect operating conditions can lead to damage to the heating
system and put safe operation at risk. Ensure that the installation
location adheres to the information included in this manual.
Failure to do so could result in property damage, serious personal
injury, or death. Failure of the water heater or components due
to incorrect operating conditions IS NOT covered by product
warranty.
LP-608-A
11/15/16
24" MIN.
3" MIN.
6" MIN.
6" MIN.
This water heater must be installed upright in the vertical position as
described in this manual. DO NOT attempt to install this water heater
in any other orientation. Doing so will result in improper water
heater operation and property damage, and could result in serious
personal injury or death.
NOTE:
To save on heating costs and improve energy efficiency keep
the distance between the water heater and fixtures to a minimum
to reduce heat loss from excess piping and keep friction loss at a
minimum. Ensure all water heater piping is properly insulated to
minimize heat loss.
possible to read or view some product labeling. It is recommended
to make note of the water heater model and serial number.
NOTE:
A combustible door or removable panel is acceptable front