6 MAINTENANCE 

6.1 GENERAL 

INFORMATION 

1.  The instrument you purchased is a precision instrument. While using and storing the 

instrument, carefully observe the recommendations listed in this manual in order to 
prevent possible damage or danger during use. 

2. Do not use the instrument in environments with high humidity levels or high 

temperatures. Do not expose to direct sunlight. 

3.  Always switch off the instrument after use. In case the instrument is not to be used for a 

long time, remove the battery to avoid liquid leaks that could damage the instrument

internal circuits. 

 

6.2  RECHARGING THE INTERNAL BATTERY 

The instrument is designed to be supplied with a Li-ION rechargeable battery. With symbol 

” 

shown on the display, it is necessary to recharge the battery. 

 

 

CAUTION 

 

  The battery must not be removed from the instrument while recharging. 

  Recharge the battery at environmental temperature and, anyway, in a 

range between 

0°C

 and 

50°C

 (32°F and 122°F). 

  When using the instrument for the first time, recharge the battery for at 

least 

6 hours

.  

 

 

1.  Connect the battery charger provided with the instrument to the AC electric mains and 

the mini USB port to the instrument's input (see Fig. 2 

– 

Part 6). The symbol 

” 

appears on the display 

2.  The charging process takes 

approximately 3 hours

. When operation is complete, 

disconnect the battery charger from the instrument and from the electric mains, when 
the display shows the symbol 

” 

of full battery charge. 

 

6.3  CLEANING THE INSTRUMENT 

Use a soft and dry cloth to clean the instrument. Never use wet cloths, solvents, water, etc. 
 

6.4  END OF LIFE 

 

 

WARNING

: this symbol found on the instrument indicates that the appliance, its 

accessories and the batteries must be collected separately and correctly 
disposed of. 

 

6.5 ACCESSORIES 
6.5.1 Accessories 

provided 

  Rechargeable Li-ION battery 

  Adapter AC/DC 100-240V/5V 

  Micro SD card, 4GB + SD card reader 

 USB 

cable 

 Tripod 

  ISO9000 calibration certificate 

 User 

manual 

 Transport 

case 

 

Содержание THT32

Страница 1: ...Copyright HT ITALIA 2016 Version EN 1 01 25 03 2016 ENGLISH User manual...

Страница 2: ...e of the object in Blending Fusion function 8 5 2 General menu description 9 5 2 1 Menu EMS 9 5 2 2 Menu UNIT 10 5 2 3 Menu MAXMIN 11 5 2 4 Menu PLT 11 5 2 5 Menu DATE 12 5 2 6 Menu MEMORY 13 5 2 7 Me...

Страница 3: ...t will guarantee safety standards They must be used only if in good conditions and replaced with identical models when necessary Check that the battery is correctly inserted Check that the LCD display...

Страница 4: ...g Fusion function 3 measuring cursors 6 standard colour palettes Automatic detection of hot cold spots of the image Storage of BMP images on external micro SD card IR sensor resolution 32x31pxl USB po...

Страница 5: ...ease contact the Dealer In case the instrument should be returned please follow the instructions given in 8 3 2 INSTRUMENT POWER SUPPLY The instrument is supplied by 1x3 7V rechargeable Li ION battery...

Страница 6: ...ENT Fig 1 Description of the instrument s front and backside CAPTION 1 LCD display 2 Function keys Menu Enter 3 Grip 4 In built visual photo camera 5 IR sensor 6 USB port for connecting AC adapter bat...

Страница 7: ...connecting AC adapter battery charger 7 Trigger key T 8 Battery compartment cover 9 Hole for tripod insertion Fig 3 Description of the instrument s inputs and outputs CAPTION 1 Inside of the battery...

Страница 8: ...Keys The arrow keys allow setting system parameters in the instrument s general menu and defining percentage and distance of the Blending Fusion function see The arrow keys also allow scrolling throu...

Страница 9: ...distance of the object in Blending Fusion function The instrument is provided with the Blending Fusion function which allows aligning the infrared and the visual image This function is therefore espec...

Страница 10: ...mit infrared radiation according to the kind of material the measured object is made of Table 1 shows the emissivity values for the most common materials Emissivity takes values between 0 mirror or pe...

Страница 11: ...enu key to go back to the instrument s main screen 5 2 2 Menu UNIT In this section it is possible to define the temperature measuring unit used by the instrument 1 Select the item UNIT with keys or an...

Страница 12: ...e display of MAX and MIN values on the display 3 Press the Menu key to confirm go back to the general menu and to the instrument s main screen 5 2 4 Menu PLT In this section it is possible to select t...

Страница 13: ...l selection 2 Use the or keys to select the options Date or Time and press the Enter key to confirm The following screen appears on the instrument s display Fig 11 System date time setting Configurati...

Страница 14: ...de 6 Press the Enter key to confirm deletion of the image 7 Press the Menu key to go back to the general menu and to the instrument s main screen 5 2 7 Menu BGT In this section it is possible to set t...

Страница 15: ...nd press the Enter key The screen appears on the display Fig 14 Setting of alarm thresholds on measurements 2 Use the or keys to select the options High or Low and press the Enter key to confirm The s...

Страница 16: ...confirm go back to the general menu and to the instrument s main screen 5 2 10 Menu DIST In this section it is possible to set the measurement unit of distance associated with the Blending Fusion func...

Страница 17: ...reen 5 2 12 Menu INFO In this section it is possible to read the general information of the instrument and the residual memory space of the fitted micro SD card 1 Select the item INFO with keys or and...

Страница 18: ...nstrument displays the temperature values associated with the measuring cursors 5 Use the trigger key T to freeze the image The following screen appears on the display Fig 19 Image saving 6 Press the...

Страница 19: ...environmental temperature and anyway in a range between 0 C and 50 C 32 F and 122 F When using the instrument for the first time recharge the battery for at least 6 hours 1 Connect the battery charge...

Страница 20: ...s on measurements MAX and MIN thresholds Memory micro SD card 4GB 6000 BMP images Max allowed micro SD card 16GB PC interface USB 2 0 Power supply Internal supply rechargeable Li ION battery 3 7V 1400...

Страница 21: ...sequence of improper packaging Repairs which may become necessary as a consequence of interventions performed by unauthorized personnel Modifications to the instrument performed without the manufactur...

Отзывы: