HT9023
EN - 50
8. TECHNICAL SPECIFICATIONS
8.1. TECHNICAL
CHARACTERISTICS
Accuracy indicated as ±[%rdg + (num digit * resolution)] referred to 23°C ± 5°C, < 80%RH
DC Voltage
Range [V]
Resolution [V]
Accuracy
Overload protection
-1500.0
1500.0
0.1
(1.0%rdg+3dgt)
1500VDC
Input impedance: 1M
Ω
;
Absolute voltage values <0.3V are zeroed
AC, AC+DC TRMS Voltage
Range [V]
Resolution [V]
Accuracy
Overload protection
0.1
999.9V
0.1
(1.0%rdg+3dgt)
1000VDC/ACrms
Input impedance: 1M
Ω
; Fundamental: 50/60Hz ± 15%, Bandwidth: 42.5Hz
1725Hz
Max. Crest Factor: 3 for voltage
≤
470Vrms, 1.41 for voltage >470Vrms
Voltage RMS values <1V and values with frequency external range
42.5Hz
1725Hz
are zeroed
DC Voltage: MAX/MIN/CREST (+/-)
Function Range [V]
Resolution [V]
Accuracy
Response time
MAX,MIN
-1500.0
1500.0
0.1
(3.5%rdg+5dgt)
200ms
CREST 1ms
Input impedance: 1M
Ω
;
Absolute voltage values <0.3V are zeroed
AC, AC+DC TRMS Voltage: MAX/MIN/CREST
Function Range [V]
Resolution [V]
Accuracy
Response time
MAX,MIN
1.0
999.9
0.1
(3.5%rdg+5dgt)
200ms
CREST
-1500.V
1500.0
1ms
Input impedance: 1M
Ω
; Fundamental: 50/60Hz ± 15%, Bandwidth: 42.5Hz
1725Hz
Max. Crest Factor: 3 for voltage
≤
470Vrms, 1.41 for voltage >470Vrms
MAX/MIN values <1V, CREST values < 1.4 and MAX/MIN/CREST values with frequency external range
42.5Hz
1725Hz
are zeroed
DC Current
Range [A]
Resolution [A]
Accuracy
Overload protection
0.1
999.9A
0.1A
(2.0%rdg+5dgt)
1000ADC/ACrms
AC, AC+DC TRMS Current
Range [A]
Resolution [A]
Accuracy
Overload protection
1.0
999.9A
0.1A
(1.0%rdg+5dgt)
1000ADC/ACrms
Fundamental: 50/60Hz ± 15%, Bandwidth: 42.5Hz
1725Hz
Max. Crest Factor: 3 for current
≤
515Arms, 1.41 for current >515A
Current RMS values <1A and values with frequency external range
42.5Hz
1725Hz
are zeroed
AC, AC+DC TRMS Current: MAX/MIN
Function Range
[A]
Resolution [A]
Accuracy
Response time
MAX, MAX
1.0
999.9A
0.1A
(3.5%rdg+5dgt)
1s
Fundamental: 50/60Hz ± 15%, Bandwidth: 42.5Hz
1725Hz
Max. Crest Factor: 3 for current
≤
515Arms, 1.41 for current >515A
MAX/MIN values <1A and MAX/MIN values with frequency external range
42.5Hz
1725Hz
are zeroed
Resistance and Continuity test
Range [
] Resolution
[
]
Accuracy
Overload protection
0.0
199.9
0.1
(2.0
rdg+5dgt)
1000VDC/ACrms
200
1999
1
2.00k
19.99k
0.01k
20.0k
29.9k
0.1k
Buzzer ON if R
RLIM, RLIM range: 1
150
Frequency (with test leads/ with jaws)
Range [Hz]
Resolution [Hz]
Accuracy
Overload protection
42.5
69.0Hz
0.1Hz
(1.0%rdg+5dgt)
1500VDC
1000ADC/ACrms
Voltage range for frequency measure: 0.5
1000V / Current range for frequency measure with jaws: 1
1000A